Preparation of a gold electrode modified with Au–TiO2 nanoparticles as an electrochemical sensor for the detection of mercury(II) ions

被引:1
作者
Lan Zhou
Wei Xiong
Shantang Liu
机构
[1] Wuhan Institute of Technology,School of Chemistry and Environmental Engineering
来源
Journal of Materials Science | 2015年 / 50卷
关键词
TiO2; Glassy Carbon Electrode; Deposition Time; Gold Electrode; Electrochemical Sensor;
D O I
暂无
中图分类号
学科分类号
摘要
A sensitive and selective electrochemical sensor based on Au–TiO2 nanoparticles/Chitosan/gold (Au–TiO2 NPs/Chit/gold)-modified electrode was developed for the detection of mercury ions (Hg2+), in which the composite electrode was synthesized via sol–gel method and followed by a self-assembly strategy. The morphology and microstructure of the Au–TiO2 NPs are characterized using transmission electron microscopy and X-ray diffraction. The results demonstrate the presence of a monolayer of well-dispersed Au–TiO2 NPs with an average size of 5–15 nm. The electrochemical properties of the resultant Au–TiO2 NPs/Chit/gold-modified electrode and its response to Hg2+ are studied using cyclic voltammetry and differential pulse anodic stripping voltammetry. The operational parameters that influence the deposition and stripping, such as the supporting electrolytes, pH value, deposition potential and deposition time, are carefully studied. Under optimal conditions, the as-prepared Au–TiO2 NPs/Chit/gold-modified electrode exhibits a wide linear response range of 5.0–400.0 nM with a correlation coefficient of 0.999. In addition, the limit of detection is 1.0 nM with a 240 s preconcentration (S/N = 3), which is lower than the World Health Organization and Environmental Protection Agency limits for Hg2+. The practical application of the proposed method is evaluated in a real water sample, and good results are obtained. This finding is potentially important for electrochemical sensors in environmental applications.
引用
收藏
页码:769 / 776
页数:7
相关论文
共 155 条
  • [1] Peng QM(2014)Unique lead adsorption behavior of activated hydroxyl group in two-dimensional titanium carbide J Am Chem Soc 136 4113-4116
  • [2] Guo JX(2004)Sources and remediation for mercury contamination in aquatic systems: a literature review Environ Pollut 131 323-336
  • [3] Zhang QR(2013)Development of a highly selective voltammetric sensor for nanomolar detection of mercury ions using glassy carbon electrode modified with a novel ion imprinted polymeric nanobeads and multi-wall carbon nanotubes J Electroanal Chem 693 16-22
  • [4] Xiang JY(2012)Synthesis of folding flake-like CuO sub-microstructure and its application on mercury(II) sensor J Mater Sci 23 858-864
  • [5] Liu BZ(2009)Chitosan modified ordered mesoporous silica as micro-column packing materials for on-line flow injection-inductively coupled plasma optical emission spectrometry determination of trace heavy metals in environmental water samples Talanta 78 491-497
  • [6] Zhou AG(2011)Analysis of trace metals (Cu, Cd, Pb, and Fe) in seawater using single batch nitrilotriacetate resin extraction and isotope dilution inductively coupled plasma mass spectrometry Anal Chim Acta 686 93-101
  • [7] Liu RP(2009)Determination of metal content in honey by atomic absorption and emission spectrometries Trends Anal Chem 28 117-128
  • [8] Tian YJ(2011)A solid phase extraction of ultra traces mercury(II) using octadecyl silica membrane disks modified by 1,3-bis(2-ethoxyphenyl)triazene (EPT) ligand and determination by cold vapor atomic absorption spectrometry J Hazard Mater 192 1358-1363
  • [9] Wang QR(2008)Priority pollutants in wastewater and combined sewer overflow Sci Total Environ 407 263-272
  • [10] Kim D(2010)Analytical approaches for Hg determination in wastewater samples by means of total reflection X-ray fluorescence spectrometry Talanta 82 821-827