Ti–Zr–Cu–Fe–Sn–Si–Ag–Ta bulk metallic glasses with good corrosion resistance as potential biomaterials

被引:0
作者
Ying Liu
Hao-Jie Wang
Shu-Jie Pang
Tao Zhang
机构
[1] Beihang University,Key Laboratory of Aerospace Materials and Performance (Ministry of Education), School of Materials Science and Engineering
[2] Beihang University,School of Physics and Nuclear Energy Engineering
[3] Beihang University,Beijing Advanced Innovation Centre for Biomedical Engineering
来源
Rare Metals | 2020年 / 39卷
关键词
Ti-based alloy; Bulk metallic glass; Glass forming ability; Bio-corrosion resistance; Mechanical properties;
D O I
暂无
中图分类号
学科分类号
摘要
Ti47Cu38−xZr7.5Fe2.5Sn2Si1Ag2Tax (x = 1–4; at%, the same below) bulk metallic glasses (BMGs) with good bio-corrosion resistance and mechanical properties were fabricated by copper mold casting. Critical diameter of the Ti-based BMGs with 1 at%–4 at% Ta was 3 mm. The Ta-incorporated Ti-based BMGs exhibit higher open current potential and parallel passive current density in comparison with those of Ti–6Al–4V alloy in 0.9 wt% NaCl and Hank’s solution, implying their good corrosion resistance. The pitting corrosion potential of the Ti-based BMGs gradually increases up to about 1.25 V with Ta addition increasing up to 4 at% in 0.9 wt% NaCl solution. Among the present Ti-based BMGs, the alloy bearing 2 at% Ta exhibits the optimal integration of mechanical properties, including the compressive fracture strength exceeding 2000 MPa, relative low Young’s modulus of 98 GPa, plastic strain of 3.4% and high hardness of HV 599. The Ta-bearing Ti-based bulk metallic glasses with integration of relative high GFA, good mechanical properties and high bio-corrosion resistance are beneficial for biomedical applications.
引用
收藏
页码:688 / 694
页数:6
相关论文
共 128 条
[11]  
Li HF(2000)Stabilization of metallic supercooled liquid and bulk amorphous alloys Acta Mater 48 279-undefined
[12]  
Sun LL(1993)Confusion by design Nature 366 303-undefined
[13]  
Li Y(2009)Effect of similar elements on improving glass-forming ability of La–Ce-based alloys J Alloys Compd 483 60-undefined
[14]  
Zhang T(2003)Corrosion of bio implants Sadhana 28 601-undefined
[15]  
Liu Y(2004)Pitting corrosion of bulk glass-forming zirconium-based alloys J Alloys Compd 377 290-undefined
[16]  
Wang G(2002)Evaluation techniques of metallic biomaterials in vitro Sci Technol Adv Mater 3 289-undefined
[17]  
Li HF(2005)Bulk metallic glass formation in Zr–Cu–Fe–Al alloys Appl Phys Lett 86 3-undefined
[18]  
Pang SJ(2015)Glass formation and properties of Ti-based bulk metallic glasses as potential biomaterials with Nb addition Rare Met 52 40-undefined
[19]  
Chen KW(2000)New applications for tantalum and tantalum alloys JOM 47 1934-undefined
[20]  
Zhang T(2006)Corrosion behavior of Ti-based metallic glasses Mater Trans 54 1368-undefined