Most of the clinical studies on the results of MIPO (minimally invasive plate osteosynthesis) with the use of anatomically preshaped locking plates for the complex distal femoral fractures have shown favorable results. In the application of bridge plating, placement of lag screws to the butterfly fragments is usually not recommended because it may make the whole construct too stiff. Recently, problems of nonunion related to excessive stiffness after MIPO using a locked plate were reported but the only solution suggested was reoperation with a bone graft. We herein report a case of nonunion after MIPO of the distal femoral fracture where we applied a concept of “dynamization of the plate-bone construct” to make it less stiff and in turn to get fracture healing with bridging callus formation. A 58-year-old woman sustained a simple oblique fracture of the distal femur (AO-OTA 33A1). We performed MIPO procedure using a locking compression plate-distal femur. To get the alignment, we have placed a conventional screw across the fracture line through the dynamic compression unit (DCU) of the combination hole. Postoperative radiographs revealed 7–8 mm gap across the entire fracture surface which was not obvious on the intra-operative C-arm images. Radiographs taken 6 months after operation showed almost no callus formation with shuttle marginal resorption. We interpreted the situation that the construct was too stiff to allow motion across the fracture site due to the lag screw. We thought we have used it as a reduction screw but it acted as a lag screw, preventing motion at the fracture site. Given this analysis, we have only taken the lag screw out to make the construct less stable. It caused the situation of absolute stability with a significant gap to turn into the one of relative stability with acceptable gap. Fracture has solidly healed with bridging callus formation 6 months after lag screw removal under local anesthesia. We would like to call this strategy as “dynamization” of the locked plating.
引用
收藏
页码:535 / 539
页数:4
相关论文
共 86 条
  • [1] Egol KA(2004)Biomechanics of locked plates and screws J Orthop Trauma 18 488-493
  • [2] Kubiak EN(2002)Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology J Bone Joint Surg Br B 84-1110
  • [3] Fulkerson E(2008)Does locked plating of periprosthetic supracondylar femur fractures promote bone healing by callus formation? Two cases with opposite outcomes Iowa Orthop J 28 73-76
  • [4] Kummer FJ(2008)The current status of locked plating: the good, the bad, and the ugly J Orthop Trauma 22 479-486
  • [5] Koval KJ(2006)The evolution of locked plates J Bone Jt Surg Am 88 189-200
  • [6] Perren SM(2004)Failure of less invasive stabilization system plates in the distal femur: a report of four cases J Orthop Trauma 18 565-570
  • [7] Henderson CE(2004)Early results of the less invasive stabilization system for mechanically unstable fractures of the distal femur (AO/OTA types A2, A3, C2, and C3) J Orthop Trauma 18 503-508
  • [8] Bottlang M(2002)Distal femur fractures with complex articular involvement: management by articular exposure and submuscular fixation Orthop Clin North Am 33 153-175
  • [9] Marsh JL(2001)Distal femoral fractures and LISS stabilization Injury 32 SC55-SC63
  • [10] Fitzpatrick DC(2001)Minimally invasive fracture stabilization of distal femoral fractures with the LISS: a prospective multicenter study. Results of a clinical study with special emphasis on difficult cases Injury 32 SC48-SC54