Validation of continuous cardiac output technologies: consensus still awaited

被引:0
作者
Maurizio Cecconi
Andrew Rhodes
机构
[1] St George's Hospital,Department of General Intensive Care
来源
Critical Care | / 13卷
关键词
Cardiac Output; Pulmonary Artery Catheter; Aviation Industry; Continuous Cardiac Output; Haemodynamic Monitoring;
D O I
暂无
中图分类号
学科分类号
摘要
An ability to measure cardiac output in a continuous and non-invasive fashion is eagerly awaited in the field of intensive care practice. Modern technologies purport to be able to do this, but the design of studies that validate the manufacturers' claims is by no means straightforward. It is imperative that the scientific community describes and agrees on a set of principles that will enable us to design and then review and assess future validation studies, so that new technologies can be fairly assessed and compared with their competitors.
引用
收藏
相关论文
共 50 条
  • [31] Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients
    Bendjelid, K.
    Marx, G.
    Kiefer, N.
    Simon, T. P.
    Geisen, M.
    Hoeft, A.
    Siegenthaler, N.
    Hofer, C. K.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (04) : 573 - 579
  • [32] Response time of the Opti-Q continuous cardiac output pulmonary artery catheter in the urgent mode to a step change in cardiac output
    Goldstein, LJ
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (7-8) : 435 - 439
  • [33] Response Time of the Opti-Q Continuous Cardiac Output Pulmonary Artery Catheter in the Urgent Mode to a Step Change in Cardiac Output
    Lawrence J. Goldstein
    Journal of Clinical Monitoring and Computing, 1999, 15 : 435 - 439
  • [34] Cardiac Output Measurement Using the Ultrasonic Cardiac Output Monitor: A Validation Study in Newborn Infants
    Fraga, Maria, V
    Dysart, Kevin C.
    Rintoul, Natalie
    Chaudhary, Aasma S.
    Ratcliffe, Sarah J.
    Fedec, Anysia
    Kren, Stephanie
    Cohen, Meryl S.
    Kirpalani, Haresh
    NEONATOLOGY, 2019, 116 (03) : 260 - 268
  • [35] A comparison of bolus versus continuous cardiac output in an experimental model of heart failure
    O'Malley, P
    Smith, B
    Hamlin, R
    Nickel, J
    Nakayama, T
    MacVicar, M
    Mann, B
    CRITICAL CARE MEDICINE, 2000, 28 (06) : 1985 - 1990
  • [36] Evaluation of a new invasive continuous cardiac output monitoring system: the truCCOMS system
    Stéphane Thierry
    Dominique Thebert
    Elsa Brocas
    Fereshte Razzaghi
    Andry Van de Louw
    Daniel Loisance
    Jean Louis Teboul
    Intensive Care Medicine, 2003, 29 : 2096 - 2099
  • [37] Evaluation of a new invasive continuous cardiac output monitoring system: the truCCOMS system
    Thierry, S
    Thebert, D
    Brocas, E
    Razzaghi, F
    Van de Louw, A
    Loisance, D
    Teboul, JL
    INTENSIVE CARE MEDICINE, 2003, 29 (11) : 2096 - 2099
  • [38] Evaluation of the accuracy and response time of STAT-mode continuous cardiac output
    Lazor, MA
    Pierce, ET
    Stanley, GD
    Cass, JL
    Halpern, EF
    Bode, RH
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1997, 11 (04) : 432 - 436
  • [39] Clinical validation of bioreactance for the measurement of cardiac output in pregnancy
    Ling, H. Z.
    Gallardo-Arozena, M.
    Company-Calabuig, A. M.
    Nicolaides, K. H.
    Kametas, N. A.
    ANAESTHESIA, 2020, 75 (10) : 1307 - 1313
  • [40] Noninvasive cardiac output monitoring (NICOM): a clinical validation
    Pierre Squara
    Dominique Denjean
    Philippe Estagnasie
    Alain Brusset
    Jean Claude Dib
    Claude Dubois
    Intensive Care Medicine, 2007, 33 : 1191 - 1194