Three-dimensional Echocardiography of the Mitral Valve Leaflet Anatomy and Repair

被引:0
作者
Chandra S. [1 ]
Sugeng L. [1 ]
Lang R.M. [1 ]
机构
[1] University of Chicago, Chicago, IL, 60637, MC 5084
关键词
Mitral regurgitation; Mitral valve; Mitral valve repair; Real-time three-dimensional echocardiography;
D O I
10.1007/s12410-010-9035-7
中图分类号
学科分类号
摘要
Three-dimensional echocardiography (3DE) has made tremendous strides in the past decade and its promise of a seamless integration into clinical practice is being increasingly realized. Its realistic views of the mitral valve (MV) provide a unique surgical perspective. From its detailed morphologic characteristics to its reproducible quantitative analysis of the MV, 3DE's role in complex MV disease has become indispensible. In this article we review the current utilization of 3DE and its incremental role over two-dimensional echocardiography in various clinical situations, including etiologic classification and severity of degenerative MV disease, understanding the complex geometric changes and interactions of the MV components in ischemic mitral regurgitation, and facilitation of surgical and percutaneous MV repair by intra-procedural guidance as well as reliable post-repair assessment. © 2010 Springer Science+Business Media, LLC.
引用
收藏
页码:268 / 275
页数:7
相关论文
共 47 条
[1]  
Bonow R.O., Carabello B.A., Chatterjee K., Et al., 2008 focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to revise the 1998 guidelines for the management of patients with valvular heart disease). Endorsed by the Society of Cardiovascular Anesthesiologi, J Am Coll Cardiol, 52, (2008)
[2]  
Garcia-Orta R., Moreno E., Vidal M., Et al., Three-dimensional versus two-dimensional transesophageal echocardiography in mitral valve repair, J Am Soc Echocardiogr, 20, pp. 4-12, (2007)
[3]  
Otsuji Y., Handschumacher M.D., Schwammenthal E., Et al., Insights from three-dimensional echocardiography into the mechanism of functional mitral regurgitation: direct in vivo demonstration of altered leaflet tethering geometry, Circulation, 96, pp. 1999-2008, (1997)
[4]  
Levine R.A., Handschumacher M.D., Sanfilippo A.J., Et al., Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse, Circulation, 80, pp. 589-598, (1989)
[5]  
Watanabe N., Ogasawara Y., Yamaura Y., Et al., Quantitation of mitral valve tenting in ischemic mitral regurgitation by transthoracic real-time three-dimensional echocardiography, J Am Coll Cardiol, 45, pp. 763-769, (2005)
[6]  
Zamorano J., Cordeiro P., Sugeng L., Et al., Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation: an accurate and novel approach, J Am Coll Cardiol, 43, pp. 2091-2096, (2004)
[7]  
Sugeng L., Coon P., Weinert L., Et al., Use of real-time 3-dimensional transthoracic echocardiography in the evaluation of mitral valve disease, J Am Soc Echocardiogr, 19, pp. 413-421, (2006)
[8]  
Hung J., Lang R., Flachskampf F., Et al., 3D echocardiography: a review of the current status and future directions, J Am Soc Echocardiogr, 20, pp. 213-233, (2007)
[9]  
Salgo I.S., Gorman J.H., Gorman R.C., Et al., Effect of annular shape on leaflet curvature in reducing mitral leaflet stress, Circulation, 106, pp. 711-717, (2002)
[10]  
Levine R.A., Weyman A.E., Handschumacher M.D., Three-dimensional echocardiography: techniques and applications, Am J Cardiol, 69, (1992)