Percutaneous Screw Fixation and Cementoplasty to Stabilize Unstable Osteolytic Fracture of Odontoid Process: a Case Report

被引:0
作者
Loïc Grange
Rémi Grange
Sylvain Bertholon
Stéphanie Morisson
Cécile Vassal
Marie-Charlotte Tetard
Sylvain Grange
机构
[1] Saint-Etienne University Hospital,Department of Interventional Radiology
[2] Lucien Neuwirth Cancer Institute,Department of supportive care in Oncology
[3] Lucien Neuwirth Cancer Institute,Department of Oncology
[4] Lucien Neuwirth Cancer Institute,Department of Radiology
[5] Saint-Etienne University Hospital,Department of Neurosurgery
关键词
Percutaneuous screw fixation; Interventional radiology; CT guide imaging; Odontoid process;
D O I
10.1007/s42399-021-01018-8
中图分类号
学科分类号
摘要
We relay a case of unstable lytic secondary fracture of odontoid process (C2) treated by screw fixation and cementoplasty, using a percutaneous approach. A 62-year-old female patient followed for a breast neoplasia with bone concurrent metastases suffered from diffuse cervical pain. A CT scan showed a lytic fracture of C2. The procedure was performed using CT scan guidance under general anesthesia. After a biphasic enhanced CT scan of the neck and cervical spine, a needle was slowly inserted to hydrodissect the jugulocarotid and prevertebral spaces up to the anterior cortex of C2 using an iodinated contrast agent solution diluted 5% with saline water. Under fluoroscopy guidance and intermittent CT monitoring, a bone pin was navigated though the anterior cortex of C2 and then advanced inside the vertebral body of C2. After checking for optimal positioning of the bone pin, a 34-mm-long titanium screw was inserted into C2 until reaching the posterior cortex. The approach to the transverse fracture line of the body of the odontoid was tangential with no displacement of the bony parts. Cement injection was then performed. One month after the procedure, a CT scan showed no material displacement, and the patient had no visible skin scarring. The patient regained full mobility of the cervical spine, and the pain decreased from 7/10 before the procedure to 0/10 after the procedure according to the patient. Percutaneous screw fixation and cementoplasty to stabilize unstable osteolytic fracture of odontoid process are safe and feasible.
引用
收藏
页码:2326 / 2328
页数:2
相关论文
共 46 条
  • [21] Acute fractures of the odontoid process: A critical analysis of anterior screw fixation in 53 cases
    Veres, R
    Casey, ATH
    Crockard, HA
    Pentelenyi, T
    JOURNAL OF NEUROSURGERY, 1996, 84 (02) : 746 - 746
  • [22] Percutaneous Fixation by Internal Cemented Screw for the Treatment of Unstable Osseous Disease in Cancer Patients
    Deschamps, Frederic
    Yevich, Steven
    Gravel, Guillaume
    Roux, Charles
    Hakime, Antoine
    de Baere, Thierry
    Tselikas, Lambros
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 2018, 35 (04) : 238 - 247
  • [23] OBLIQUE ODONTOID FRACTURE - CASE-REPORT AND REVIEW OF THE LITERATURE
    KATOH, S
    ELMASRY, WS
    INMAN, CG
    PARAPLEGIA, 1994, 32 (02): : 108 - 111
  • [24] Benign osteoblastoma of the odontoid process of the axis: A case report
    Mori, Y
    Takayasu, M
    Saito, K
    Seki, Y
    Shibuya, M
    Yoshida, J
    SURGICAL NEUROLOGY, 1998, 49 (03): : 274 - 277
  • [25] Diagnostic pitfalls in osteomyelitis of the odontoid process: Case report
    Noguchi, S
    Yanaka, K
    Yamada, Y
    Nose, T
    SURGICAL NEUROLOGY, 2000, 53 (06): : 573 - 578
  • [26] Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation
    Kevin M. Baskin
    Ann Marie Cahill
    Robin D. Kaye
    Christopher T. Born
    Jan S. Grudziak
    Richard B. Towbin
    Pediatric Radiology, 2004, 34 : 963 - 969
  • [27] Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation
    Baskin, KM
    Cahill, AM
    Kaye, RD
    Born, CT
    Grudziak, JS
    Towbin, RB
    PEDIATRIC RADIOLOGY, 2004, 34 (12) : 963 - 969
  • [28] Percutaneous screw fixation of a vertebral pedicle fracture under CT-guidance: A new technique
    Amoretti, Nicolas
    Marcy, Pierre-Yves
    Hauger, Olivier
    Browaeys, Patrick
    Amoretti, Marie-eve
    Hoxorka, Istvan
    Boileau, Pascal
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : 591 - 593
  • [29] Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process
    Sung, Min-Jae
    Kim, Kyoung-Tae
    Hwang, Jeong-Hyun
    Sung, Joo-Kyung
    Cho, Dae-Chul
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2018, 61 (04) : 503 - 508
  • [30] Spontaneous odontoid fracture on a tophus responsible for spinal cord compression: A case report
    Deparisot, Audrey
    Ltaief-Boudrigua, Aicha
    Villani, Axel-Patrice
    Barrey, Cedric
    Chapurlat, Roland D.
    Confavreux, Cyrille B.
    JOINT BONE SPINE, 2013, 80 (05) : 550 - 551