Novel non-invasive method of measurement of endothelial function: enclosed-zone flow-mediated dilatation (ezFMD)

被引:0
作者
Teiji Ukawa
Tsuneo Takayanagi
Haruka Morimoto
Yukihito Higashi
Naomi Idei
Masao Yoshizumi
Toshio Tsuji
机构
[1] Nihon Kohden Corporation,Department of Regeneration and Medicine, Research Institute for Radiation Biology and Medicine, Research Center for Radiation Genome Medicine
[2] Hiroshima University,Department of Cardiovascular Physiology and Medicine
[3] Hiroshima University Graduate School of Biomedical Sciences,Department of Cardiovascular Medicine
[4] Hiroshima University Graduate School of Biomedical Sciences,undefined
[5] Hiroshima University Graduate School of Engineering,undefined
来源
Medical & Biological Engineering & Computing | 2012年 / 50卷
关键词
Atherosclerosis; Endothelial function; FMD; Oscillometric sphygmomanometer; ezFMD;
D O I
暂无
中图分类号
学科分类号
摘要
Measurement of flow-mediated dilatation (FMD) is the conventional non-invasive method for assessment of endothelial function; however, it requires an expensive ultrasound system and high levels of technical skill. Therefore, we developed a novel method for measurement of endothelial function, namely, measurement of ezFMD. ezFMD estimates the degree of vasodilatation from the oscillation signals transmitted to a sphygmomanometer cuff attached to the upper arm. The objective of this study was to validate the principle underlying the measurement of ezFMD, and to evaluate the repeatability of the ezFMD measurements. We observed the blood vessel behavior and oscillometric pattern in ten subjects. When the cuff was inflated to the level of the mean blood pressure, the oscillation amplitude increased with increasing degree of vasodilatation. In experiment to evaluate the repeatability of the ezFMD measurement, the average difference between the paired measurements was 3.7 %, the standard deviation was 11.5 %, and the average coefficient of variation value for the 11 paired measurements was 23.7 %. These results suggest the validity of the principle underlying the measurement of the ezFMD for the assessment of endothelial function. And, this study suggests that the repeatability of the ezFMD measurements is superior to that of the conventional measurement of FMD.
引用
收藏
页码:1239 / 1247
页数:8
相关论文
共 91 条
[1]  
Bank AJ(1995)Direct effect of smooth muscle relaxation and contraction on in vivo human brachial artery elastic properties Circ Res 77 1008-1016
[2]  
Wilson RF(1986)Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 307-310
[3]  
Kubo H(1992)Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis Lancet 340 1111-1115
[4]  
Holte JE(1999)The assessment of methods of measurements Stat Med 9 351-362
[5]  
Dresing TJ(2002)Guidelines for the ultrasound assessment of endothelial-dependent flow mediated vasodilation of the brachial artery: a report of the International Brachial Artery Reactivity Task Force J Am Coll Cardiol 39 257-265
[6]  
Wang H(2006)Variability of flow-mediated dilation measurements with repetitive reactive hyperemia Vasc Med 11 1-6
[7]  
Bland JM(2004)Repeatability of noninvasive surrogates of endothelial function Am J Cardiol 94 693-696
[8]  
Altman DG(1980)The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure—part II J Biomech Eng 102 28-33
[9]  
Celermajer DS(2005)Flow-mediated vasodilation predicts outcome in patients with chronic heart failure: comparison with B-type natriuretic peptide J Am Coll Cardiol 46 1011-1018
[10]  
Sorensen KE(2005)Changes in arterial pressure during mechanical ventilation Anesthesiology 103 419-428