Development of a bar adsorptive micro-extraction–large-volume injection–gas chromatography–mass spectrometric method for pharmaceuticals and personal care products in environmental water matrices

被引:0
作者
N. R. Neng
J. M. F. Nogueira
机构
[1] University of Lisbon,Faculty of Sciences, Chemistry and Biochemistry Department and Center of Chemistry and Biochemistry
来源
Analytical and Bioanalytical Chemistry | 2012年 / 402卷
关键词
Sorption-based methods; Bar adsorptive micro-extraction (BAμE); PPCPs; LVI-GC-MS(SIM); Environmental water matrices; Trace analysis;
D O I
暂无
中图分类号
学科分类号
摘要
The combination of bar adsorptive micro-extraction using activated carbon (AC) and polystyrene–divinylbenzene copolymer (PS-DVB) sorbent phases, followed by liquid desorption and large-volume injection gas chromatography coupled to mass spectrometry, under selected ion monitoring mode acquisition, was developed for the first time to monitor pharmaceutical and personal care products (PPCPs) in environmental water matrices. Assays performed on 25 mL water samples spiked (100 ng L−1) with caffeine, gemfibrozil, triclosan, propranolol, carbamazepine and diazepam, selected as model compounds, yielded recoveries ranging from 74% to 99% under optimised experimental conditions (equilibrium time, 16 h (1,000 rpm); matrix characteristics: pH 5, 5% NaCl for AC phase; LD: methanol/acetonitrile (1:1), 45 min). The analytical performance showed good precision (RSD < 18%), convenient detection limits (5–20 ng L−1) and excellent linear dynamic range (20–800 ng L−1) with remarkable determination coefficients (r2 > 0.99), where the PS-DVB sorbent phase showed a much better efficiency. By using the standard addition methodology, the application of the present analytical approach on tap, ground, sea, estuary and wastewater samples allowed very good performance at the trace level. The proposed method proved to be a suitable sorption-based micro-extraction alternative for the analysis of priority pollutants with medium-polar to polar characteristics, showing to be easy to implement, reliable, sensitive and requiring a low sample volume to monitor PPCPs in water matrices.
引用
收藏
页码:1355 / 1364
页数:9
相关论文
共 66 条
[1]  
Fatta D(2007)undefined TrAC Trends Anal Chem 26 515-533
[2]  
Achilleos A(2006)undefined Chemosphere 64 1808-1817
[3]  
Nikolaou A(2009)undefined Anal Chem 81 4645-4677
[4]  
Meriç S(2003)undefined Chemosphere 51 69-75
[5]  
Moldovan Z(2010)undefined Anal Bioanal Chem 396 1853-1862
[6]  
Richardson SD(2008)undefined J Chromatogr A 1209 10-16
[7]  
Koutsouba V(2010)undefined Anal Chem 82 4742-4774
[8]  
Heberer T(2008)undefined Talanta 74 1498-1504
[9]  
Fuhrmann B(2007)undefined J Chromatogr A 1161 132-145
[10]  
Schmidt-Baumler K(2003)undefined J Pharm Biomed Anal 32 569-579