Heating performance of a ground source heat pump system installed in a school building

被引:0
作者
Jaedo Song
Kwangho Lee
Youngman Jeong
Seongir Cheong
Jaekeun Lee
Yujin Hwang
Yeongho Lee
Donghyuk Lee
机构
[1] Pusan National University,School of Mechanical Engineering
[2] LG Electronics,undefined
来源
Science in China Series E: Technological Sciences | 2010年 / 53卷
关键词
ground source heat pump (GSHP); water-to-refrigerant; heating performance; coefficient of performance (COP); air source heat pump (ASHP);
D O I
暂无
中图分类号
学科分类号
摘要
The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP (ground source heat pump) system during the winter season of 2008. Ten heat pump equipments with the capacity of 10 HP each and a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth were constructed. We investigated a variety of working conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger in order to examine the heating performance of the GSHP system. Subsequently, the heating capacity and the input power were investigated to determine the heating performance of the GSHP system. The average heating coefficient of performance (COP) of the heat pump was noted to be 5.1 at partial load of 47%, while the overall system COP was found to be 4.2. Also, performance of the GSHP system was compared with that of air source heat pump.
引用
收藏
页码:80 / 84
页数:4
相关论文
共 36 条
[1]  
Michopoulos A.(2007)Three-year operation experience of a ground source heat pump system in Northern Greece Energy Build 39 328-334
[2]  
Bozis D.(2006)Development of a design and performance prediction tool for the ground source heat pump Appl Thermal Eng 26 1578-1592
[3]  
Kikidis P.(2003)Experimental study of a closed loop vertical ground source heat pump system Energy Conv Manage 44 527-548
[4]  
Nagano K.(2005)Direct application of geothermal energy Geothermics. 200534 691-727
[5]  
Katsura T.(1998)Effect of climatic conditions on the design optimization of heat pump systems for space heating and cooling Energy Conv Manage 39 609-622
[6]  
Takeda S.(1998)Economic potential of vertical ground-source heat pumps compared to air-source air conditioners in South Africa Energy 23 137-143
[7]  
Hepbasli A.(2001)A performance comparison between an air-source and a ground-source reversible heat pump Int J Energy Res 25 899-8910
[8]  
Akdemir O.(2005)Cooling and heating performance evaluation of a GSHP system Korean J Air-Cond Refrig Eng 17 71-81
[9]  
Hancioglu E.(2006)District heating system design for a university campus Energy Build, 2006 37 1111-1119
[10]  
Lund J. W.(2004)Ground source heat pump-description and preliminary results of the Eco House system Appl Thermal Eng 24 2627-2641