Sampling and determination of gas phase divalent mercury in the air using a KCl coated denuder

被引:0
|
作者
Z. Xiao
J. Sommar
S. Wei
O. Lindqvist
机构
[1] Department of Inorganic Chemistry,
[2] Chalmers University of Technology and University of Göteborg,undefined
[3] S-412 96,undefined
[4] Göteborg,undefined
[5] Sweden,undefined
关键词
Mercury; Laboratory Test; Sampling Location; SnCl2; Average Efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
KCl coated denuders were employed for the measurement of divalent mercury (Hg2+) species in the air. Laboratory tests show that gaseous Hg2+ can be collected by the denuder with an average efficiency of 98% and elemental Hg will pass through it freely. Hg2+ trapped in the denuder can be quantitatively extracted by 1 mol/L HCl and analyzed by the method of SnCl2 reduction-CVAFS determination. Hg2+ concentrations of 0.04–0.15 ng m–3 corresponding to about 2–9% of the total gaseous mercury in the ambient air were determined at several sampling locations.
引用
收藏
页码:386 / 391
页数:5
相关论文
共 50 条
  • [1] Sampling and determination of gas phase divalent mercury in the air using a KCl coated denuder
    Xiao, Z
    Sommar, J
    Wei, S
    Lindqvist, O
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (03): : 386 - 391
  • [2] Determination of gaseous divalent mercury in ambient air using KCl coated denuders
    Feng, XB
    Sommar, J
    Lindqvist, O
    Zhu, YX
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (06) : 682 - 685
  • [3] Improved determination of gaseous divalent mercury in ambient air using KCl coated denuders
    Feng, XB
    Sommar, J
    Gårdfeldt, K
    Lindqvist, O
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (05): : 423 - 428
  • [4] Improved determination of gaseous divalent mercury in ambient air using KCl coated denuders
    Xinbin Feng
    J. Sommar
    K. Gårdfeldt
    O. Lindqvist
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 423 - 428
  • [5] REMOVAL OF GASEOUS MERCURY FROM AIR USING A GOLD COATED DENUDER
    MUNTHE, J
    SCHROEDER, WH
    XIAO, Z
    LINDQVIST, O
    ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1990, 24 (08): : 2271 - 2274
  • [6] Comparison of conventional filtration and a denuder-based methodology for sampling of particulate-phase mercury in ambient air
    Lu, JY
    Schroeder, WH
    TALANTA, 1999, 49 (01) : 15 - 24
  • [7] DENUDER-BASED TECHNIQUES FOR SAMPLING, SEPARATION AND ANALYSIS OF GASEOUS AND PARTICULATE MERCURY IN AIR
    KVIETKUS, K
    XIAO, Z
    LINDQVIST, O
    WATER AIR AND SOIL POLLUTION, 1995, 80 (1-4): : 1209 - 1216
  • [8] Development and characterization of an annular denuder methodology for the measurement of divalent inorganic reactive gaseous mercury in ambient air
    Landis, MS
    Stevens, RK
    Schaedlich, F
    Prestbo, EM
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (13) : 3000 - 3009
  • [9] Gas chromatographic determination of formaldehyde in air using solid-phase microextraction sampling
    Bolta, SV
    Zupancic-Kralj, L
    Marsel, J
    CHROMATOGRAPHIA, 1998, 48 (1-2) : 95 - 100
  • [10] Gas chromatographic determination of formaldehyde in air using solid-phase microextraction sampling
    Ŝ. Velikonja Bolta
    L. Zupanĉiĉ-Kralj
    J. Marsel
    Chromatographia, 1998, 48 : 95 - 100