Experimental study on the effects of the number of heat exchanger modules on thermal characteristics in a premixed combustion system

被引:0
作者
Byeonghun Yu
Sung-Min Kum
Chang-Eon Lee
Seungro Lee
机构
[1] Inha University,Department of Mechanical Engineering
[2] Halla University,School of Mechanical and Automotive Engineering
[3] Chonbuk National University,Department of Mechanical Engineering
来源
Journal of Mechanical Science and Technology | 2016年 / 30卷
关键词
Premixed combustion system; Staggered-tube array; Heat exchanger modules; Entropy generation;
D O I
暂无
中图分类号
学科分类号
摘要
The effects of the number of heat exchanger modules on thermal characteristics were experimentally studied in a premixed combustion system with a cross-flow staggered-tube heat exchanger. The various heat exchanger modules, from 4 to 8, combined with a premixed burner were tested to investigate the performance of the heat exchanger through the surface area of the heat exchanger at various equivalence ratios. Additionally, the performance of the heat exchanger was analyzed by applying entropy generation theory to the heat exchanger system. As a result, although the heat transfer rate increases with the increase of the equivalence ratio, the NOx and CO concentrations also increase due to the increasing flame temperature. In addition, the entropy generation increases with an increase of the equivalence ratio. Furthermore, the heat transfer rate and the effectiveness are increased with the increase of the number of the heat exchanger modules. Also, the effectiveness is sharply increased when the number of the heat exchanger modules is increased from 4 to 5. Consequently, the optimal operating conditions regarding pollutant emission, effectiveness and entropy generation in this experimental range are 0.85 for the equivalence ratio and 8 for the number of heat exchanger modules.
引用
收藏
页码:447 / 456
页数:9
相关论文
共 54 条
[1]  
Kim J. Y.(2003)Effect of tube alignment on the heat/mass transfer from a plate fin and two-tube assembly: naphthalene sublimation results Int. J. Heat Mass Transf. 46 3051-3059
[2]  
Song T. H.(2013)Experimental study on thermal-hydraulic performance of a wavy fin-and-flat tube aluminum heat exchanger Appl. Therm. Eng. 51 32-39
[3]  
Dong J.(2004)Heat transfer and fluid flow analysis in plate-fin and tube heat exchangers with a pair of block shape vortex generators Int. J. Heat Mass Transf. 47 4327-4338
[4]  
Su L.(2012)Development of an adhesive-bonded counterflow microchannel heat exchanger Appl. Therm. Eng. 48 194-201
[5]  
Chen Q.(2011)The effects of configurations on the performance of microchannel counter-flow heat exchangers-An experimental study Appl. Therm. Eng. 31 3946-3955
[6]  
Xu W.(2009)Experimental investigation of fluid flow and heat transfer in a single-phase liquid flow micro-heat exchanger Int. J. Heat Mass Transf. 52 5433-5446
[7]  
Leu J. S.(2009)Influence of channel geometry on the performance of a counter flow microchannel heat exchanger Int. J. Therm. Sci. 48 1607-1618
[8]  
Wu Y. H.(2009)Investigating the efficacy of nanofluids as coolants in plate heat exchangers (PHE) Chem. Eng. Sci. 64 3290-3300
[9]  
Jang J. Y.(2010)Characteristics of Thermal Efficiency with Changing Distances Between Tubes for Heat Exchanger Journal of Energy Engineering 19 177-181
[10]  
Paulraj P.(2011)A study on the combustion characteristics of flat-plate premixed burner for various flame surface media and heat exchangers Journal of KSME B 35 1033-1040