Influence of lasing parameters on the cleaning efficacy of laser-activated irrigation with pulsed erbium lasers

被引:0
|
作者
Maarten A. Meire
Sophie Havelaerts
Roeland J. De Moor
机构
[1] Ghent University,Department of Restorative Dentistry and Endodontology, Dental School
来源
Lasers in Medical Science | 2016年 / 31卷
关键词
Root canal irrigation; Laser-activated irrigation; Erbium laser; Pulse length; Pulse energy; Fibre tip shape;
D O I
暂无
中图分类号
学科分类号
摘要
Laser-activated irrigation (LAI) using erbium lasers is an irrigant agitation technique with great potential for improved cleaning of the root canal system, as shown in many in vitro studies. However, lasing parameters for LAI vary considerably and their influence remains unclear. Therefore, this study sought to investigate the influence of pulse energy, pulse frequency, pulse length, irradiation time and fibre tip shape, position and diameter on the cleaning efficacy of LAI. Transparent resin blocks containing standardized root canals (apical diameter of 0.4 mm, 6 % taper, 15 mm long, with a coronal reservoir) were used as the test model. A standardized groove in the apical part of each canal wall was packed with stained dentin debris. The canals were filled with irrigant, which was activated by an erbium: yttrium aluminium garnet (Er:YAG) laser (2940 nm, AT Fidelis, Fotona, Ljubljana, Slovenia). In each experiment, one laser parameter was varied, while the others remained constant. In this way, the influence of pulse energy (10–40 mJ), pulse length (50–1000 μs), frequency (5–30 Hz), irradiation time (5–40 s) and fibre tip shape (flat or conical), position (pulp chamber, canal entrance, next to groove) and diameter (300–600 μm) was determined by treating 20 canals per parameter. The amount of debris remaining in the groove after each LAI procedure was scored and compared among the different treatments. The parameters significantly (P < 0.05, Kruskal–Wallis) affecting debris removal from the groove were fibre tip position, pulse length, pulse energy, irradiation time and frequency. Fibre tip shape and diameter had no significant influence on the cleaning efficacy.
引用
收藏
页码:653 / 658
页数:5
相关论文
共 50 条
  • [21] Pulsed hollow-cathode ion lasers: pumping and lasing parameters
    Zinchenko, S. P.
    Ivanov, I. G.
    QUANTUM ELECTRONICS, 2012, 42 (06) : 518 - 523
  • [22] Effectiveness of Laser-activated Irrigation Modalities on Intracanal Bacterial Elimination and Apical Extrusion
    Abbas, Mohamed Marwan
    Yadadi, Sunaina Shetty
    Sulaiman, Ashna
    Mahmoud, Okba
    Jamleh, Ahmed
    AL Shehadat, Saaid
    EUROPEAN ENDODONTIC JOURNAL, 2025, 10 (01): : 35 - 40
  • [23] Comparative Safety of Needle, EndoActivator, and Laser-Activated Irrigation in Overinstrumented Root Canals
    Sen, Ozgur Genc
    Kaya, Melih
    PHOTOMEDICINE AND LASER SURGERY, 2018, 36 (04) : 198 - 202
  • [24] The Impact of Laser-Activated and Conventional Irrigation Techniques on Sealer Penetration into Dentinal Tubules
    Koruk, Dilara
    Basmaci, Fatma
    Kirmizi, Dilan
    Aksoy, Umut
    PHOTOBIOMODULATION PHOTOMEDICINE AND LASER SURGERY, 2022, 40 (08) : 565 - 572
  • [25] Optimisation of the pumping parameters of a repetitively pulsed erbium laser
    Byshevskaya-Konopko, LO
    Vorob'ev, IL
    Izyneev, AA
    Sadovskii, PI
    Sergeev, SN
    QUANTUM ELECTRONICS, 2001, 31 (10) : 861 - 863
  • [26] The influence of laser-activated irrigation on post-operative pain following root canal treatment: A systematic review
    McGillivray, Alex
    Dutta, Arindam
    JOURNAL OF DENTISTRY, 2024, 144
  • [27] Real-time intracanal temperature measurement comparing mechanically and laser-activated irrigation to syringe irrigation
    Donnermeyer, David
    Schaefer, Edgar
    Buerklein, Sebastian
    AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (01) : 59 - 66
  • [28] INFLUENCE OF STRUCTURE PARAMETERS ON LASING CHARACTERISTICS OF SEMICONDUCTOR-LASERS
    MATSUMOTO, N
    KUMABE, K
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1979, 18 (02) : 321 - 332
  • [29] Measurement of pressure changes during laser-activated irrigant by an erbium, chromium: yttrium, scandium, gallium, garnet laser
    Harry Huiz Peeters
    Roeland J. G. De Moor
    Lasers in Medical Science, 2015, 30 : 1449 - 1455
  • [30] Comparison of a Novel Modality of Erbium-Doped Yttrium Aluminum Garnet Laser-Activated Irrigation and Ultrasonic Irrigation against Mature Enterococcus faecalis Biofilm-An In Vitro Study
    Petricevic, Gabrijela Kapetanovic
    Percinic, Antonio
    Budimir, Ana
    Sesar, Anja
    Anic, Ivica
    Bago, Ivona
    BIOENGINEERING-BASEL, 2024, 11 (10):