Influence of lasing parameters on the cleaning efficacy of laser-activated irrigation with pulsed erbium lasers

被引:0
作者
Maarten A. Meire
Sophie Havelaerts
Roeland J. De Moor
机构
[1] Ghent University,Department of Restorative Dentistry and Endodontology, Dental School
来源
Lasers in Medical Science | 2016年 / 31卷
关键词
Root canal irrigation; Laser-activated irrigation; Erbium laser; Pulse length; Pulse energy; Fibre tip shape;
D O I
暂无
中图分类号
学科分类号
摘要
Laser-activated irrigation (LAI) using erbium lasers is an irrigant agitation technique with great potential for improved cleaning of the root canal system, as shown in many in vitro studies. However, lasing parameters for LAI vary considerably and their influence remains unclear. Therefore, this study sought to investigate the influence of pulse energy, pulse frequency, pulse length, irradiation time and fibre tip shape, position and diameter on the cleaning efficacy of LAI. Transparent resin blocks containing standardized root canals (apical diameter of 0.4 mm, 6 % taper, 15 mm long, with a coronal reservoir) were used as the test model. A standardized groove in the apical part of each canal wall was packed with stained dentin debris. The canals were filled with irrigant, which was activated by an erbium: yttrium aluminium garnet (Er:YAG) laser (2940 nm, AT Fidelis, Fotona, Ljubljana, Slovenia). In each experiment, one laser parameter was varied, while the others remained constant. In this way, the influence of pulse energy (10–40 mJ), pulse length (50–1000 μs), frequency (5–30 Hz), irradiation time (5–40 s) and fibre tip shape (flat or conical), position (pulp chamber, canal entrance, next to groove) and diameter (300–600 μm) was determined by treating 20 canals per parameter. The amount of debris remaining in the groove after each LAI procedure was scored and compared among the different treatments. The parameters significantly (P < 0.05, Kruskal–Wallis) affecting debris removal from the groove were fibre tip position, pulse length, pulse energy, irradiation time and frequency. Fibre tip shape and diameter had no significant influence on the cleaning efficacy.
引用
收藏
页码:653 / 658
页数:5
相关论文
共 104 条
[1]  
Paque F(2011)Accumulated hard tissue debris levels in mesial roots of mandibular molars after sequential irrigation steps Int Endod J 44 148-153
[2]  
Boessler C(2009)Irrigant flow within a prepared root canal using various flow rates: a computational fluid dynamics study Int Endod J 42 144-155
[3]  
Zehnder M(2001)A primary observation on the preparation and obturation of oval canals Int Endod J 34 137-141
[4]  
Boutsioukis C(2009)Review of contemporary irrigant agitation techniques and devices J Endod 35 791-804
[5]  
Lambrianidis T(2009)Laser-activated irrigation within root canals: cleaning efficacy and flow visualization Int Endod J 42 1077-1083
[6]  
Kastrinakis E(2007)Cavitation as a working mechanism of the Er, Cr:YSGG laser in endodontics: a visualization study J Oral Laser Appl 7 97-106
[7]  
Wu MK(2009)Laser induced explosive vapor and cavitation resulting in effective irrigation of the root canal. Part 1: a visualization study Lasers Surg Med 41 514-519
[8]  
Wesselink PR(2011)Visualization of irrigant flow and cavitation induced by Er:YAG laser within a root canal model J Endod 37 839-843
[9]  
Gu LS(1993)Studies of acoustical and shock waves in the pulsed laser ablation of biotissue Lasers Surg Med 13 470-484
[10]  
Kim JR(2009)Laser induced explosive vapor and cavitation resulting in effective irrigation of the root canal. Part 2: evaluation of the efficacy Lasers Surg Med 41 520-523