A comparison of postoperative sore throat after use of laryngeal mask airway and tracheal tube

被引:2
作者
Mizutamari E. [1 ]
Yano T. [1 ]
Ushijima K. [1 ]
Ito A. [2 ]
Anraku S. [1 ]
Tanimoto H. [3 ]
Terasaki H. [4 ]
机构
[1] Dept. of Anesthesiol./Surgical Ctr., Kumamoto University Hospital, Kumamoto 860-8556
[2] Department of Anesthesiology, Kumamoto Chuo Hospital, Kumamoto
[3] Department of Anesthesiology, Kumamoto National Hospital, Kumamoto
[4] Department of Anesthesiology, Graduate School of Medical Sciences, Kumamoto University, Kumamoto
关键词
Airway management; Anesthesia; Complications;
D O I
10.1007/s00540-004-0234-8
中图分类号
学科分类号
摘要
Purpose. We compared the degree of postoperative sore throat (PST) after use of a laryngeal mask airway (LMA; by two insertion techniques) and a tracheal tube (TT) in adult patients. Methods. Eighty-six adult patients undergoing surgery of an extremity were randomized into three groups. The LMAs (size 4 for men, 3 for women) and TTs were lubricated with 2% lidocaine gel. After the induction of anesthesia, an LMA with the cuff deflated was inserted and then the cuff was inflated in group A, an LMA with the cuff inflated was inserted in group B, and the trachea was intubated using vecuronium in group C; staff anesthesiologists performed all these methods. LMA cuffs were inflated with the maximum recommended volume of air. TT cuffs were inflated with the minimum volume of air without gas leakage at 20 cm H2O pressure. The mode of ventilation depended on the individual anesthesiologists. Blood traces on the devices were examined after their removal. PST was rated immediately after anesthesia and on the first postoperative day, using a three-point score and a 100-mm visual analog scale, respectively. Results. Most of the patients receiving an LMA breathed spontaneously and those receiving a TT underwent controlled ventilation. The ratio of positive blood traces on devices, as well as the degree of PST immediately after anesthesia, was similar in the three groups; however, on the first postoperative day, the severity of PST was greater in the LMA groups than in the TT group (P = 0.016). The severity of PST was similar with the two LMA insertion techniques. Conclusion. In the conditions of our study, LMAs inserted with the cuff either fully inflated or deflated worsened PST compared with TTs. © JSA 2004.
引用
收藏
页码:151 / 157
页数:6
相关论文
共 30 条
  • [1] McHardy F.E., Chung F., Postoperative sore throat: Cause, prevention and treatment, Anaesthesia, 54, pp. 444-453, (1999)
  • [2] Higgins P.P., Chung F., Mezei G., Postoperative sore throat after ambulatory surgery, Br. J. Anaesth., 88, pp. 582-584, (2002)
  • [3] Joshi G.P., Inagaki Y., White P.F., Taylor-Kennedy L., Wat L.I., Gevirtz C., McCraney J.M., McCulloch D.A., Use of the laryngeal mask airway as an alternative to the tracheal tube during ambulatory anesthesia, Anesth. Analg., 85, pp. 573-577, (1997)
  • [4] Fujii Y., Tanaka H., Toyooka H., Effects of laryngeal mask airway on circulation and on incidence of postoperative sore throat and hoarseness, Masui (Jpn. J. Anesth.), 42, pp. 1659-1662, (1993)
  • [5] Saeki H., Morimoto Y., Yamashita A., Nagusa Y., Shimizu K., Oka H., Miyauchi Y., Postoperative sore throat and intracuff pressure: Comparison among endotracheal intubation, laryngeal mask airway and cuffed oropharyngeal airway, Masui (Jpn. J. Anesth.), 48, pp. 1328-1331, (1999)
  • [6] Rieger A., Brunne B., Hass I., Brummer G., Spies C., Striebel H.W., Eyrich K., Laryngo-pharyngeal complaints following laryngeal mask airway and endotracheal intubation, J. Clin. Anesth., 9, pp. 42-47, (1997)
  • [7] Splinter W.M., Smallman B., Rhine E.J., Komocar L., Post-operative sore throat in children and the laryngeal mask airway, Can. J. Anaesth., 41, pp. 1081-1083, (1994)
  • [8] Wakeling H.G., Butler P.J., Baxter P.J., The Laryngeal mask airway: A comparison between two insertion techniues, Anesth. Analg., 85, pp. 687-690, (1997)
  • [9] Benumof J.L., Management of the difficult adult airway. With special emphasis on awake tracheal intubation, Anesthesiology, 75, pp. 1087-1110, (1991)
  • [10] Keller C., Puhringer F., Brimacombe J.R., Influence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway, Br. J. Anaesth., 81, pp. 86-187, (1998)