Enhanced aminophenols monitoring using in-channel amperometric detection with dual-channel microchip capillary electrophoresis

被引:0
作者
Chuanpin Chen
Jong Hoon Hahn
机构
[1] Pohang University of Science and Technology,Department of Chemistry, BK School of Molecular Science
来源
Environmental Chemistry Letters | 2011年 / 9卷
关键词
Aminophenol; Capillary electrophoresis (CE); Dual-channel; Electrochemical detection (; Environmental monitoring; Microchip;
D O I
暂无
中图分类号
学科分类号
摘要
Improved techniques are needed to monitor toxic aminophenols in industrial wastewater. Microchip capillary electrophoresis (CE)-electrochemical detection (ECD) can be used to develop miniaturized system providing on-site monitoring. Here, a dual-channel microchip CE-ECD has been applied for the monitoring of aminophenols. The effect of conductance and capacitance between a working electrode and a reference electrode has been studied to minimize the noise that was generated in the amperometric detection. A mixture of aminophenols dissolved in a running buffer has been monitored. A separation efficiency with a plate number of 4770 and a high linear concentration dependence from 100 nM to 1 mM have been achieved for p-aminophenol. As a result, the analysis system has been applied for the monitoring of the pollutants with low detection limits of p-aminophenol (14.6 nM), o-aminophenol (10.6 nM) and m-aminophenol (15.3 nM). Here, we show that a wastewater sample from a natural gas refinery can be monitored using the microchip CE-ECD system.
引用
收藏
页码:491 / 497
页数:6
相关论文
共 140 条
  • [1] Cekic SD(2005)Simultaneous spectrophotometric determination of paracetamol and J Anal Chem 60 1019-1023
  • [2] Filik H(2007)-aminophenol in pharmaceutical products with tiron using dissolved oxygen as oxidant Anal Chem 79 7182-7186
  • [3] Apak R(2006)Dual-channel method for interference-free in-channel amperometric detection in microchip capillary electrophoresis Talanta 68 497-503
  • [4] Chen C(2007)Monitoring environmental pollutants by microchip capillary electrophoresis with electrochemical detection Talanta 71 1944-1950
  • [5] Hahn JH(2008)A thin cover glass chip for contactless conductivity detection in microchip capillary electrophoresis Electrophoresis 29 310-323
  • [6] Chen G(1998)Recent advances in CE and CEC of pollutants Anal Chem 70 4974-4984
  • [7] Lin Y(2000)Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) Electroanalysis 12 677-684
  • [8] Wang J(2000)Microfabricated ultramicroelectrode arrays: developments, advances, and applications in environmental analysis Crit Care Nurse 20 69-74
  • [9] Chen Z(2004)Acute acetaminophen overdose in adolescents and adults Anal Bioanal Chem 379 1062-1067
  • [10] Li Q(2002)Poly(dimethylsiloxane) microchip capillary electrophoresis with electrochemical detection for rapid measurement of acetaminophen and its hydrolysate Electrophoresis 23 3649-3658