Reproducibility of Laplacian Wall Thickness Measurements of the Gallbladder with Varying CT Slice Thickness

被引:0
|
作者
M. N. Prasad
M. S. Brown
C. Ni
D. Margolis
M. Douek
S. Raman
D. Lu
J. G. Goldin
S. K. Warfield
机构
[1] University of California,Department of Radiological Sciences, David Geffen School of Medicine
[2] Children’s Hospital Boston,Department of Radiology
来源
关键词
CT; Ultrasound; Laplace’s equation; Thickness; Reproducibility;
D O I
暂无
中图分类号
学科分类号
摘要
In measuring changes of gallbladder wall thickness using CT, robustness to differences in acquisition protocols including slice thickness can be important. We have developed an automated technique based on Laplace’s equation to measure the gallbladder wall thickness using computer tomography (CT). The purpose of this work is to investigate the usefulness of the Laplacian technique in obtaining gallbladder wall thickness measurements that are reproducible with variations in CT slice thickness. This study included 2D (2D) and 3D (3D) wall thickness measurements using Laplace’s equation. Ten subjects who had 5 mm (thick) and 2.5 mm (thin) reconstruction (from a single set of raw data) through the abdomen were randomly selected from a research database. Their volumetric CT images were acquired using a multidetector GE MEDICAL SYSTEMS–LightSpeed 16 scanner at 120 KVP, ~250 mAs, with standard filter reconstruction algorithm and manually segmented on all CT cross sections by a radiologist. The inner and outer boundaries of the gallbladder wall were obtained from the segmentation. The thickness of the wall was quantified by computing the distance between the boundaries for each scan and over the entire volume using Laplace’s equation from mathematical physics. The distance between the surfaces is found by computing normalized gradients that form a vector field. The vector fields represent tangent vectors along field lines connecting both boundaries. The Laplacian technique was compared with the conventional Euclidean distance transformation (EDT) technique using coefficient of variation. EDT results in an Euclidean distance mapping between the two extracted surfaces. Both techniques were compared in 2D and 3D. For the 2D and 3D wall thickness measurements, a mean difference of 0.35 and 0.25 mm between thin and thick reconstruction was found respectively using Laplace’s equation. EDT resulted in a higher mean difference for both 2D and 3D. In addition, a significant difference in thickness between the Laplacian technique and EDT techniques (p < 0.001) were obtained. The Laplacian measurement of gallbladder wall showed significantly lower variation compared to EDT on different CT slice thickness for both 2D and 3D techniques. Hence, proving to be an important technique for obtaining reproducible wall thickness measurements of the gallbladder using CT.
引用
收藏
页码:67 / 75
页数:8
相关论文
共 50 条
  • [1] Reproducibility of Laplacian Wall Thickness Measurements of the Gallbladder with Varying CT Slice Thickness
    Prasad, M. N.
    Brown, M. S.
    Ni, C.
    Margolis, D.
    Douek, M.
    Raman, S.
    Lu, D.
    Goldin, J. G.
    Warfield, S. K.
    JOURNAL OF SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2009, 55 (1-3): : 67 - 75
  • [2] Reproducibility of airway wall thickness measurements
    Schmidt, Michael
    Kuhnigk, Jan-Martin
    Krass, Stefan
    Owsijewitsch, Michael
    de Hoop, Bartjan
    Peitgen, Heinz-Otto
    MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624
  • [3] Reproducibility of airway wall thickness measurements on CT in a lung cancer screening setting
    Pompe, Esther
    Schmidt, Michael
    Van Rikxoort, Eva
    Vliegenthart, Rozemarijn
    Oudkerk, Matthijs
    De Koning, Harry
    Van Ginneken, Bram
    De Jong, Pim
    Lammers, Jan-Willem
    Hoesein, Firdaus Mohamed
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [4] GALLBLADDER WALL THICKNESS
    SPAULDING, KA
    VETERINARY RADIOLOGY & ULTRASOUND, 1993, 34 (04) : 270 - 272
  • [5] SLICE THICKNESS MEASUREMENTS
    GOLDSTEIN, A
    JOURNAL OF ULTRASOUND IN MEDICINE, 1988, 7 (09) : 487 - 498
  • [6] REPRODUCIBILITY OF CAROTID VESSEL WALL THICKNESS MEASUREMENTS - THE ROTTERDAM STUDY
    BOTS, ML
    MULDER, PGH
    HOFMAN, A
    VANES, GA
    GROBBEE, DE
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 1994, 47 (08) : 921 - 930
  • [7] Reproducibility of arterial compliance and carotid wall thickness measurements in normal subjects
    Liang, YL
    Cameron, JD
    Teede, H
    Kotsopoulos, D
    McGrath, BP
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1998, 25 (7-8) : 618 - 620
  • [8] REPRODUCIBILITY OF CAROTID VESSEL WALL THICKNESS MEASUREMENTS - THE ROTTERDAM ELDERLY STUDY
    BOTS, ML
    MULDER, PG
    HOFMAN, A
    GROBBEE, DE
    CIRCULATION, 1993, 87 (02) : 687 - 687
  • [9] WALL THICKNESS MEASUREMENTS
    MINTON, WC
    MATERIALS PROTECTION, 1969, 8 (12): : 41 - &
  • [10] Reproducibility of coronary artery calcium measurements using 0.8-mm-thickness 256-slice coronary CT
    Soe Hee Ann
    Jae Hee Kim
    Nam Du Ha
    Seong Hoon Choi
    Scot Garg
    Gillian Balbir Singh
    Eun-Seok Shin
    Japanese Journal of Radiology, 2014, 32 : 677 - 684