Experimental investigation of progressive collapse potential of ordinary and special moment-resisting reinforced concrete frames

被引:0
作者
Tarek Almusallam
Yousef Al-Salloum
Tuan Ngo
Priyan Mendis
Husain Abbas
机构
[1] King Saud University,MMB Chair of Research and Studies in Strengthening and Rehabilitation of Structures, Department of Civil Engineering, College of Engineering
[2] The University of Melbourne,Department of Infrastructure Engineering
来源
Materials and Structures | 2017年 / 50卷
关键词
Progressive collapse; Reinforced concrete; Ordinary moment-resisting frame; Special moment-resisting frame; Catenary action; Plastic mechanism; RC; Column removal;
D O I
暂无
中图分类号
学科分类号
摘要
Two one-quarter-scaled, single-story, two-bay by one-bay, reinforced concrete (RC) building frame models—one each for ordinary and special moment-resisting frames (OMRF and SMRF) conforming to ACI 318 Building Code Requirements for Structural Concrete and Commentary—were tested for progressive collapse, with the objective of studying the difference in the response of the two schemes of reinforcement detailing. The load was applied at 100 mm/s on the failed middle column with 50 mm incremental vertical displacement in each loading cycle. The tests help to develop a better understanding of how connections in the floor systems perform when subjected to large deformations, as well as large catenary and membrane forces. The mechanical behavior of the models has been discussed and analyzed using a simplified model that may be used for the assessment of progressive collapse potential of RC building frames by incorporating the catenary mechanism. The collapse load for OMRF and SMRF models estimated by plastic mechanism was 62.8 and 75.5% of the tested failure capacity, respectively. The special reinforcement detailing of RC building frames (as done in SMRF) is found to help considerably in mitigation of the progressive collapse of building frames.
引用
收藏
相关论文
共 86 条
  • [1] Ishikawa N(2007)Lessons from past explosive tests on protective structures in Japan Int J Impact Eng 34 1535-1545
  • [2] Beppu M(2006)Practical means for energy-based analyses of disproportionate collapse potential J Perform Constr Fac ASCE 20 336-348
  • [3] Dusenberry DO(1978)Approaches for design against progressive collapse J Struct Div ASCE 104 413-423
  • [4] Hamburger RO(2008)Progressive collapse of multi-storey buildings due to sudden column loss—Part I: simplified assessment framework Eng Struct 30 1308-1318
  • [5] Ellingwood BR(2010)Residual strength of blast damaged reinforced concrete columns Int J Impact Eng 37 295-308
  • [6] Leyendecker EV(2008)Pressure–impulse diagrams for the behavior assessment of structural components Int J Impact Eng 35 771-783
  • [7] Izzuddin BA(2011)Development of P-I diagrams for FRP strengthened RC columns Int J Impact Eng 38 290-304
  • [8] Vlassis AG(2008)Numerical derivation of pressure–impulse diagrams for prediction of RC column damage to blast loads Int J Impact Eng 35 1213-1227
  • [9] Elghazouli AY(2011)Residual axial compression capacity of localized blast-damaged RC columns Int J Impact Eng 38 29-40
  • [10] Nethercot DA(2010)Progressive collapse analysis of a RC building subjected to blast loads Int J Struct Eng Mech 36 301-319