Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences

被引:0
|
作者
S. Heiland
O. Dietrich
K. Sartor
机构
[1] Department of Neuroradiology,
[2] University of Heidelberg Medical School,undefined
[3] Im Neuenheimer Feld 400,undefined
[4] 69 120 Heidelberg,undefined
[5] Germany e-mail: Sabine_Heiland@med.uni-heidelberg.de Tel.: + 49-62 21-56 75 66 Fax: + 49-62 21-56 46 73,undefined
来源
Neuroradiology | 2001年 / 43卷
关键词
Key words Diffusion-weighted imaging; Echo planar imaging; Pulse sequences;
D O I
暂无
中图分类号
学科分类号
摘要
We used a rat model of focal cerebral ischaemia to compare stimulated-echo (STE) and spin-echo (SE) echo planar (EPI) diffusion-weighted sequences as regards image quality and accuracy of calculation of apparent diffusion coefficients (ADC). Focal cerebral ischaemia was induced by endovascular occlusion of the middle cerebral artery in five rats. MRI was performed on a 2.35 tesla imager. For diffusion-weighted imaging (DWI) we used STE-EPI and SE-EPI with different diffusion times (Δ) of 15, 30, 45, 60, 75 and 90 ms using values of b of 200, 300, 400, 500, 600 and 700 s/mm2. We assessed image quality, the signal-to-noise-ratio (SNR) and the accuracy of the ADC calculated from both sequences. Infarcts were delineated in all cases, independent of sequence type and Δ. The image quality and SNR of the SE-EPI images were significantly better, with a higher SNR than STE-EPI images for short and intermediate values of Δ. However, when Δ reached 75 ms STE-EPI became superior to SE-EPI. ADC calculated from STE-EPI images were smaller than those from SE-EPI images for short and intermediate diffusion times, possibly because of the lower SNR of the former. We suggest that SE-EPI sequences be used for DWI of the brain, particularly on experimental systems and whole-body imagers with enhanced gradient hardware, where it is possible to run highly diffusion-weighted sequences (b > 500 s/mm2) with Δ less than 50 ms. However, when using very long values of Δ because of hardware restrictions or for measurement of restricted diffusion, STE sequences give better results.
引用
收藏
页码:442 / 447
页数:5
相关论文
共 50 条
  • [1] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    Heiland, S
    Dietrich, O
    Sartor, K
    NEURORADIOLOGY, 2001, 43 (06) : 442 - 447
  • [2] Radiological diagnosis of acute stroke -: Comparison of conventional MR imaging, echo-planar diffusion-weighted imaging, and spin-echo diffusion-weighted imaging
    Geijer, B
    Brockstedt, S
    Lindgren, A
    Ståhlberg, F
    Norrving, B
    Holtås, S
    ACTA RADIOLOGICA, 1999, 40 (03) : 255 - 262
  • [3] Diffusion-weighted imaging of the spinal cord: Interleaved echo-planar imaging is superior to fast spin-echo
    Bammer, R
    Augustin, M
    Prokesch, RW
    Stollberger, R
    Fazekas, F
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) : 364 - 373
  • [4] Diffusion-weighted imaging of the brain at 7 T with echo-planar and turbo spin echo sequences: preliminary results
    Sigmund, Eric E.
    Gutman, David
    MAGNETIC RESONANCE IMAGING, 2011, 29 (06) : 752 - 765
  • [5] Intravoxel incoherent motion diffusion-weighted imaging in nasopharyngeal carcinoma: comparison of the turbo spin-echo and echo-planar imaging techniques
    Liu, Yuan
    Hu, Liu
    Qian, Lijuan
    Chen, Manman
    Xu, Si
    Sun, Peng
    Huang, Jing
    Lei, Ziqiao
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 9101 - 9111
  • [6] Intravoxel Incoherent Motion Diffusion-Weighted Imaging of Lung Cancer: Comparison Between Turbo Spin-Echo and Echo-Planar Imaging
    Wan, Qi
    Lei, Qiang
    Wang, Peng
    Hu, Jianfeng
    Zhang, Tianjing
    Yu, Deng
    Li, Xinchun
    Liang, Changhong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (03) : 334 - 340
  • [7] Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck
    Ryoji Mikayama
    Hidetake Yabuuchi
    Shinjiro Sonoda
    Koji Kobayashi
    Kazuya Nagatomo
    Mitsuhiro Kimura
    Satoshi Kawanami
    Takeshi Kamitani
    Seiji Kumazawa
    Hiroshi Honda
    European Radiology, 2018, 28 : 316 - 324
  • [8] Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck
    Mikayama, Ryoji
    Yabuuchi, Hidetake
    Sonoda, Shinjiro
    Kobayashi, Koji
    Nagatomo, Kazuya
    Kimura, Mitsuhiro
    Kawanami, Satoshi
    Kamitani, Takeshi
    Kumazawa, Seiji
    Honda, Hiroshi
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 316 - 324
  • [9] Increased-contrast, high-spatial-resolution, diffusion-weighted, spin-echo, echo-planar imaging
    Thompson, MR
    Venkatesan, R
    Kuppusamy, K
    Celik, A
    Lin, WL
    Kido, DK
    Haacke, EM
    RADIOLOGY, 1999, 210 (01) : 253 - 259
  • [10] Evaluation of Thin-slice Coronal Single-shot Turbo Spin-echo Diffusion-weighted Imaging of the Hand: A Comparison with Conventional Echo-planar Diffusion-weighted Imaging
    Ogawa, Masaki
    Nakagawa, Motoo
    Arai, Nobuyuki
    Kan, Hirohito
    Ohba, Shota
    Shibata, Shunsuke
    Maki, Hiroyuki
    Shibamoto, Yuta
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (04) : 382 - 388