Water-enhanced antegrade MR pyelography in pregnancy: a novel radiation-free approach

被引:1
|
作者
Allen G.N. [1 ]
Buckley B.W. [2 ]
Conroy D.M. [3 ]
Lundon D.J. [1 ,2 ]
MacMathuna P. [1 ]
O’Malley K. [1 ]
Lawler L.P. [1 ]
Ridge C.A. [1 ]
机构
[1] Mater Misericordiae University Hospital, Dublin
[2] University College Dublin, Dublin
[3] Belfast City Hospital, Belfast
关键词
Antegrade MR pyelography; Magnetic resonance imaging; Percutaneous nephrostomy; Pregnancy; Urologic diseases;
D O I
10.1186/s41747-017-0019-0
中图分类号
学科分类号
摘要
Our aim was to determine if water-enhanced antegrade magnetic resonance (MR) pyelography can be an alternative to conventional antegrade pyelography in pregnant patients who require percutaneous nephrostomy placement for urosepsis and/or obstructive uropathy. The pregnant patient was placed supine in a 1.5-T MRI scanner seven days after percutaneous nephrostomy placement using ultrasound. Serial axial and coronal T2-weighted echo-planar fast spin-echo sequences were performed before and after injection of the catheter. The right nephrostomy catheter hub was sterilised using chlorhexidine. Sixty millilitres of sterile water were slowly injected. No Gd-based contrast agent was utilised due to safety concerns for the foetus. MR antegrade pyelography demonstrated the level of ureteric obstruction and the absence of renal calculi using sterile water as a contrast medium injected through a percutaneous nephrostomy followed by T2-weighted imaging. Air bubbles in the injected solution were differentiated from calculi due to their mobility on serial scans and their anti-dependent position. Water-enhanced antegrade MR pyelography was a safe and effective method of imaging the pregnant patient. It served as an alternative to conventional antegrade pyelography and minimised potential risks to the foetus. © 2017, The Author(s).
引用
收藏
相关论文
共 50 条
  • [1] Radiation-Free ERCP in Pregnancy: A “Sound” Approach to Leaving No Stone Unturned
    Saurabh Sethi
    Nirav Thosani
    Subhas Banerjee
    Digestive Diseases and Sciences, 2015, 60 : 2604 - 2607
  • [2] Radiation-Free ERCP in Pregnancy: A "Sound" Approach to Leaving No Stone Unturned
    Sethi, Saurabh
    Thosani, Nirav
    Banerjee, Subhas
    DIGESTIVE DISEASES AND SCIENCES, 2015, 60 (09) : 2604 - 2607
  • [3] RADIATION-FREE PERCUTANEOUS NEPHROLITHOTOMY(PCNL) IN PREGNANCY
    Hosseini, M. M.
    Aminsharifi, A.
    JOURNAL OF ENDOUROLOGY, 2010, 24 : A72 - A72
  • [4] RADIATION-FREE PERCUTANEOUS NEPHROLITHOTOMY(PCNL) IN PREGNANCY
    Hosseini, Mohammad M.
    Aminsharifi, Alireza
    Hagjpanah, Abdoreza
    Forootan, Mohammad
    Mostafavi, Mohammad
    Zand, Farid
    Zare, Zahra
    Amooee, Sedighe
    JOURNAL OF ENDOUROLOGY, 2011, 25 : A143 - A143
  • [5] RADIATION-FREE PERCUTANEOUS NEPHROLITHOTOMY (PCNL) IN PREGNANCY
    Hosseini, M. M.
    Aminsharifi, A. R.
    Mostafavi, M.
    EUROPEAN UROLOGY SUPPLEMENTS, 2010, 9 (06) : 604 - 604
  • [6] EVALUATION OF CF LUNG DISEASE BY MR: A RADIATION-FREE ALTERNATIVE
    Goralski, J. L.
    Birchard, K. R.
    Muhlebach, M. S.
    PEDIATRIC PULMONOLOGY, 2014, 49 : 296 - 297
  • [7] A radiation-free novel approach for intestinal stent placement: the "scope-in-scope" technique
    Hu, Jiaqing
    Zheng, Jinhui
    Yang, Changshun
    Gao, Xiang
    Guo, Xianbin
    Zheng, Xiaoling
    ENDOSCOPY, 2024, 56 : E313 - E314
  • [8] A radiation-free novel approach for intestinal stent placement: the "scope-in-scope" technique
    Hu, Jiaqing
    Zheng, Jinhui
    Yang, Changshun
    Gao, Xiang
    Guo, Xianbin
    Zheng, Xiaoling
    ENDOSCOPY, 2024, 56 (08) : 632 - 633
  • [9] Evaluation of MR-safe bioptomes for MR-guided endomyocardial biopsy in minipigs: a potential radiation-free clinical approach
    Svetlove, Angelika
    Ritter, Christian O.
    Dullin, Christian
    Schmid, Michael
    Schauer, Senta
    Uihlein, Johannes
    Uecker, Martin
    Mietsch, Matthias
    Stadelmann, Christine
    Lotz, Joachim
    Unterberg-Buchwald, Christina
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [10] Evaluation of MR-safe bioptomes for MR-guided endomyocardial biopsy in minipigs: a potential radiation-free clinical approach
    Angelika Svetlove
    Christian O. Ritter
    Christian Dullin
    Michael Schmid
    Senta Schauer
    Johannes Uihlein
    Martin Uecker
    Matthias Mietsch
    Christine Stadelmann
    Joachim Lotz
    Christina Unterberg-Buchwald
    European Radiology Experimental, 7