Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones

被引:0
作者
Dominik Gruszka
Charlotte Arand
Julia Greenfield
Tobias E. Nowak
Raphael Kuechle
Sebastian Kuhn
Pol M. Rommens
机构
[1] University Medical Center of Johannes Gutenberg University,Department of Orthopaedics and Traumatology
[2] University of Reims Champagne-Ardenne,GRESPI EA 4694, Faculty of Sport Sciences
来源
Archives of Orthopaedic and Trauma Surgery | 2017年 / 137卷
关键词
Tension band wiring; Olecranon complex fracture; Olecranon tension plate; Biomechanical study; Olecranon fixation;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1651 / 1658
页数:7
相关论文
共 100 条
[1]  
Karlsson MK(2002)Fractures of the olecranon: a 15- to 25-year followup of 73 patients Clin Orthop Relat Res 204 205-212
[2]  
Hasserius R(2004)Olecranon fractures in adults: factors influencing outcome Injury 35 1149-1157
[3]  
Karlsson C(2008)Olecranon fractures Orthop Clin N Am 39 229-236
[4]  
Rommens PM(2009)Olecranon fractures Injury 40 575-581
[5]  
Küchle R(2012)Fractures in brief: olecranon fractures Clin Orthop Relat Res 470 3637-3641
[6]  
Schneider RU(2008)Is tension band wiring technique the “gold standard” for the treatment of olecranon fractures? A long term functional outcome study J Orthop Surg Res 3 9-200
[7]  
Reuter M(2016)Factors associated with reoperation after fixation of displaced olecranon fractures Clin Orthop Relat Res 474 193-604
[8]  
Veillette CJH(2013)Olecranon fractures J Hand Surg Am 38 593-204
[9]  
Steinmann SP(2012)Tension band wiring of the olecranon: is it really a dynamic principle of osteosynthesis? Injury 224 192-372
[10]  
Newman SDS(1987)Surgical treatment of displaced olecranon fractures by tension band wiring technique Clin Orthop Relat Res 67 367-1114