Determination of the Critical Micelle Concentration of Neutral and Ionic Surfactants with Fluorometry, Conductometry, and Surface Tension—A Method Comparison

被引:0
作者
Norman Scholz
Thomas Behnke
Ute Resch-Genger
机构
[1] Federal Institute for Materials Research and Testing (BAM),Division Biophotonics
来源
Journal of Fluorescence | 2018年 / 28卷
关键词
Surfactant; CMC; Micelle; Conductometry; Surface Tension; Nile Red; DPH; Pyrene; Fluorescence; Optical probe;
D O I
暂无
中图分类号
学科分类号
摘要
Micelles are of increasing importance as versatile carriers for hydrophobic substances and nanoprobes for a wide range of pharmaceutical, diagnostic, medical, and therapeutic applications. A key parameter indicating the formation and stability of micelles is the critical micelle concentration (CMC). In this respect, we determined the CMC of common anionic, cationic, and non-ionic surfactants fluorometrically using different fluorescent probes and fluorescence parameters for signal detection and compared the results with conductometric and surface tension measurements. Based upon these results, requirements, advantages, and pitfalls of each method are discussed. Our study underlines the versatility of fluorometric methods that do not impose specific requirements on surfactants and are especially suited for the quantification of very low CMC values. Conductivity and surface tension measurements yield smaller uncertainties particularly for high CMC values, yet are more time- and substance consuming and not suitable for every surfactant.
引用
收藏
页码:465 / 476
页数:11
相关论文
共 182 条
[1]  
Ashjari M(2012)Self-assembled nanomicelles using PLGA-PEG amphiphilic block copolymer for insulin delivery: a physicochemical investigation and determination of CMC values J Mater Sci Mater Med 23 943-953
[2]  
Khoee S(2009)New urea-based surfactants derived from alpha,omega-amino acids J Phys Chem B 113 977-982
[3]  
Mahdavian AR(1986)Dye-surfactant interactions: a review Talanta 33 255-264
[4]  
Rahmatolahzadeh R(2008)Determination of critical micelle concentration (Cmc) of sodium dodecyl sulfate (SDS) and the effect of low concentration of pyrene on its Cmc using ORIGIN software J Chem Soc Pak 30 186-191
[5]  
Faustino CM(2011)Curcumin-loaded PLGA-PEG-PLGA triblock copolymeric micelles: preparation, pharmacokinetics and distribution in vivo J Colloid Interface Sci 354 116-123
[6]  
Calado AR(2012)Role of curcumin on the determination of the critical micellar concentration by absorbance, fluorescence and fluorescence anisotropy techniques J Photochem Photobiol B 115 9-15
[7]  
Garcia-Rio L(2012)Polymeric micelle stability Nano Today 7 53-65
[8]  
Garcia ME(2014)A sensitive and visible fluorescence-turn-on probe for the CMC determination of ionic surfactants Chem Commun 50 1107-1109
[9]  
Sanz-Medel A(2011)Spectroscopic determination of critical micelle concentration in aqueous and non-aqueous media using a non-invasive method J Colloid Interface Sci 364 400-406
[10]  
Khan AM(2005)New fluorescence method for the determination of the critical micelle concentration by photosensitive monoazacryptand derivatives Langmuir 21 6688-6695