A low power low noise analog front-end for ECG recording

被引:0
|
作者
Subhajit Dey
Manisha Pattanaik
Gaurav Kaushal
机构
[1] ABV-Indian Institute of Information Technology and Management,
关键词
Bio-signal amplifier; Class A–B; Low noise; Low power; ECG recording; Inverter-based;
D O I
暂无
中图分类号
学科分类号
摘要
This work presents a power-efficient and noise-efficient amplifier for ECG recordings. To improve power efficiency, all the transistors in the proposed amplifier is designed in sub-threshold region which gives high gm\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_m$$\end{document}/ID\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_D$$\end{document} ratio. To improve noise efficiency, inverter-based differential input stage is used in this proposed operational transconductance amplifier as it reduces noise by a factor of 2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\sqrt{2}$$\end{document} when compared to it’s non-inverter based counterpart. In order to decrease flicker noise, large transistors are used in the input stage. Class A–B structure is used in the output stage for achieving high gm\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_m$$\end{document}/ID\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_D$$\end{document} ratio and for large output swing range. In 180 nm process the amplifier consumes 477 nW DC power from 1.8 V supply which indicates 7.5% decrease in power consumption when compared to recently reported papers. This amplifier achieves a noise efficiency of 2.68. Common mode rejection ratio and power supply rejection ratio is estimated as 98.5 dB and 104.5 dB respectively.
引用
收藏
页码:449 / 458
页数:9
相关论文
共 50 条
  • [1] A low power low noise analog front-end for ECG recording
    Dey, Subhajit
    Pattanaik, Manisha
    Kaushal, Gaurav
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2021, 109 (02) : 449 - 458
  • [2] An Ultra Low-power Low-noise Neural Recording Analog Front-end IC for Implantable Devices
    Kim, Hyung Seok
    Cha, Hyouk-Kyu
    JOURNAL OF SEMICONDUCTOR TECHNOLOGY AND SCIENCE, 2018, 18 (04) : 454 - 460
  • [3] A Low Power ECG Acquisition System Implemented with a Fully Integrated Analog Front-End
    Cheng, Yayu
    Wang, Jun
    Wen, Meiying
    Li, Ye
    2013 IEEE INTERNATIONAL SYMPOSIUM ON LOW POWER ELECTRONICS AND DESIGN (ISLPED), 2013, : 408 - 408
  • [4] Low Power Implantable Neural Recording Front-End
    Anh Tuan Do
    Tan, YungSern
    Lam, Chunkit
    Je, Minkyu
    Yeo, Kiat Seng
    2012 INTERNATIONAL SOC DESIGN CONFERENCE (ISOCC), 2012, : 387 - 390
  • [5] A Low Power Analog Front-end for Ultrasound Receiver
    Yang, Chuanshi
    Tang, Kai
    Qiu, Lei
    Fang, Zhongyuan
    Zheng, Yuanjin
    32ND IEEE INTERNATIONAL SYSTEM ON CHIP CONFERENCE (IEEE SOCC 2019), 2019, : 484 - 487
  • [6] Low-noise low-power front-end logarithmic amplifier for neural recording system
    Derafshi, Zahra Haddad
    Frounchi, Javad
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2014, 42 (05) : 437 - 451
  • [7] A LOW-NOISE LOW-POWER FRONT-END AMPLIFIER FOR NEURAL-RECORDING APPLICATIONS
    Zarifi, Mohammad Hossein
    Frounchi, Javad
    Tinati, Mohammad A.
    Farshchi, Shahin
    Judy, Jack W.
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2010, 22 (04): : 301 - 306
  • [8] Low phase noise and low intermodulation analog front-end for an OFDM system
    Yamamoto, A
    Nishimura, K
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1998, 44 (03) : 1001 - 1011
  • [9] A low power analog front-end module for cochlear implants
    Wang, RJW
    Sarpeshkar, R
    Jabri, M
    Mead, C
    COCHLEAR IMPLANTS, 1996, : 75 - 79
  • [10] An ultrahigh input impedance low noise analog front-end design for epilepsy brain recording system
    Anh, Nguyen Thi Ngoc
    Tien, Nguyen The
    Tuan, Nguyen Van
    Tuan, Dao Duy
    Thanh, Vu Van
    Thai, Pham Quang
    Au, Huynh Hai
    Tho, Nguyen Van
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2024, 52 (11) : 5469 - 5482