Loss of excitation of SMIB power system equipped with high photovoltaic penetration with constant injected voltage

被引:0
|
作者
Mohammad S. Widyan
Majdi M. Alomari
Rolf E. Hanitsch
机构
[1] The Hashemite University,Electrical Engineering Department
[2] The Australian College of Kuwait,Electrical Engineering Department
[3] Berlin University of Technology,Institute of Energy and Automation Technology
来源
Electrical Engineering | 2017年 / 99卷
关键词
Power system transient; High PV penetration; Loss of excitation of synchronous generator;
D O I
暂无
中图分类号
学科分类号
摘要
The effect of high photovoltaic (PV) penetration with constant injected voltage on the loss of excitation phenomenon of single machine infinite bus power system with two transmission lines has been investigated. The PV modules are integrated to the power system at the same bus of the synchronous generator via DC–DC buck–boost switch mode converter, three-phase DC–AC switch mode inverter, LC filter and transformer. The constant injected voltage from the PV generator at the common coupling point at all system running conditions is achieved by controlling the duty cycle the DC–DC converter. To ensure the robustness of this integration, the system response based on a complete nonlinear dynamical mathematical model in dq stationary reference frame after step changes on the synchronous generator input mechanical power at different practical solar irradiance levels is first observed. Then, the response of the system after successive step changes on the solar irradiance levels is highlighted and compared. The loss of excitation of the synchronous generator is detected by extracting the trajectory of the impedance of the synchronous generator seen across its terminals at two practical solar irradiance levels as compared with the case of conventionally powered system without PV generator. It is concluded that the setting of the distance mho relay which works properly in case the power system is conventionally powered by the synchronous generator alone cannot detect the loss of excitation when the PV generator is integrated with the power system at all realistic solar irradiance levels. Therefore, a new setting for the distance relay has to be carried out. This new setting must be accompanied with a shift to the right such that the trajectory of the synchronous generator terminal impedance can enter the circle of the mho distance relay which in turn results in shorter tripping time in case of conventionally powered power system. All numerical simulations have been executed using MATLAB environment by constructing the code required.
引用
收藏
页码:19 / 31
页数:12
相关论文
共 50 条
  • [1] Loss of excitation of SMIB power system equipped with high photovoltaic penetration with constant injected voltage
    Widyan, Mohammad S.
    Alomari, Majdi M.
    Hanitsch, Rolf E.
    ELECTRICAL ENGINEERING, 2017, 99 (01) : 19 - 31
  • [2] Operating point stability analysis of SMIB power system equipped with high PV penetration
    Widyan, Mohammad S.
    Hanitsch, Rolf E.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 55 : 522 - 530
  • [3] Influence of Voltage Sags on the Power System with High Penetration of Photovoltaic Power Generation
    Yamashita, Koji
    Kitauchi, Yoshihiro
    Kobayashi, Hiromu
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [4] Reactive power and voltage control for high penetration photovoltaic interconnected to power grid
    Pi Zhixuan
    Liu Dong
    Huang Yuhui
    Xu Xiaochun
    Wu Xiaofei
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 2301 - 2306
  • [5] Impacts of Large Scale and High Voltage Level Photovoltaic Penetration on the Security and Stability of Power System
    Yang Weidong
    Zhou Xia
    Xue Feng
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [6] Modified direct feedback linearization Excitation Controller for transient stability and voltage regulation of SMIB power system
    Keskes, Salma
    Bouchiba, Nouha
    Sallem, Souhir
    Chrifi-Alaoui, Larbi
    Kammoun, Mba
    2018 7TH INTERNATIONAL CONFERENCE ON SYSTEMS AND CONTROL (ICSC), 2018, : 278 - 282
  • [7] Voltage Control in Low Voltage Distribution Networks with High Penetration Photovoltaic System
    Leon, J. S.
    Padilha-Feltrin, A.
    Melo, J. D.
    Sguarezi Filho, Alfeu J.
    2017 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE - LATIN AMERICA (ISGT LATIN AMERICA), 2017,
  • [8] Fundamental voltage characteristics in power system with a large penetration of photovoltaic generation
    Ishikawa, K. (ishikawa@upn.t.u-tokyo.ac.jp), 1600, Institute of Electrical Engineers of Japan (134):
  • [9] Study on the Impact of Photovoltaic Penetration on Power System Static Voltage Stability
    Liu Y.
    Yao L.
    Liao S.
    Xu J.
    Sun Y.
    Cheng F.
    Cui W.
    Li F.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (15): : 5484 - 5496
  • [10] Damping Enhancement for SMIB Power System Equipped with Partial Feedback Linearization AVR
    Kumar, Ajit
    2018 20TH NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2018,