A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions

被引:0
作者
Carlo N. De Cecco
Damiano Caruso
U. Joseph Schoepf
Domenico De Santis
Giuseppe Muscogiuri
Moritz H. Albrecht
Felix G. Meinel
Julian L. Wichmann
Philip F. Burchett
Akos Varga-Szemes
Douglas H. Sheafor
Andrew D. Hardie
机构
[1] Medical University of South Carolina,Department of Radiology and Radiological Science
[2] Oncological and Pathological Sciences University of Rome “Sapienza”,Department of Radiological Sciences
[3] University of Rome “Sapienza”,Department of Clinical and Molecular Medicine
[4] University Hospital Frankfurt,Department of Diagnostic and Interventional Radiology
[5] Ludwig Maximilian University Hospital,Institute for Clinical Radiology
来源
European Radiology | 2018年 / 28卷
关键词
Dual-energy CT; Hypervascular liver lesions; Virtual monoenergetic images; Diagnostic accuracy; Liver imaging;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:3393 / 3404
页数:11
相关论文
共 86 条
  • [1] Meier A(2015)Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography Clin Radiol 70 1244-1251
  • [2] Wurnig M(2015)The importance of spectral separation: an assessment of dual-energy spectral separation for quantitative ability and dose efficiency Invest Radiol 50 114-118
  • [3] Desbiolles L(2014)Closing in on the K edge: coronary CT angiography at 100, 80, and 70 kV-initial comparison of a second- versus a third-generation dual-source CT system Radiology 273 373-382
  • [4] Leschka S(2015)Advanced virtual monoenergetic computed tomography of hyperattenuating and hypoattenuating liver lesions: ex-vivo and patient experience in various body sizes Invest Radiol 50 695-702
  • [5] Frauenfelder T(2014)Dual-energy liver CT: effect of monochromatic imaging on lesion detection, conspicuity, and contrast-to-noise ratio of hypervascular lesions on late arterial phase AJR Am J Roentgenol 203 601-606
  • [6] Alkadhi H(2014)Objective and subjective image quality of liver parenchyma and hepatic metastases with virtual monoenergetic dual-source dual-energy CT reconstructions: an analysis in patients with gastrointestinal stromal tumor Acad Radiol 21 514-522
  • [7] Krauss B(2012)Virtual monochromatic spectral imaging for the evaluation of hypovascular hepatic metastases: the optimal monochromatic level with fast kilovoltage switching dual-energy computed tomography Invest Radiol 47 292-298
  • [8] Grant KL(2013)Spectral optimization of chest CT angiography with reduced iodine load: experience in 80 patients evaluated with dual-source, dual-energy CT Radiology 267 256-266
  • [9] Schmidt BT(2014)Dual-energy MDCT in hypervascular liver tumors: effect of body size on selection of the optimal monochromatic energy level AJR Am J Roentgenol 203 1257-1264
  • [10] Flohr TG(2014)Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media Invest Radiol 49 586-592