Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems

被引:0
|
作者
Werner Jung
Andreas Rillig
Ralf Birkemeyer
Tomislav Miljak
Udo Meyerfeldt
机构
[1] Academic Teaching Hospital Villingen of the University of Freiburg,Department of Cardiology
来源
Journal of Interventional Cardiac Electrophysiology | 2008年 / 23卷
关键词
Telecardiology; Remote monitoring; Home monitoring; Heart failure monitoring; Pacemaker follow-up;
D O I
暂无
中图分类号
学科分类号
摘要
Unlike the standard quarterly or semi-annual direct ambulatory device interrogations procedures, state-of-the-art implantable electronic cardiovascular devices (IECD) enable their wireless remote interrogation and monitoring, and automatically send reports and special alerts on a daily basis. This allows physicians to respond more proactively to changes in patient or device status, more appropriately triage patient care, and more efficiently perform the post-implant ambulatory follow-ups. This review presents the-state-of the-art technology of remote IECD monitoring and summarizes the main clinical observations published through June 2008. Cardiovascular remote monitoring systems made by several manufacturers are currently in various phases of development, clinical investigation, and medical applications. Data collected in several completed and ongoing studies strongly suggest that this new technology will make important contributions, particularly with respect to the facilitation of IECD follow-ups, enhancement of patient safety and quality of life, and lowering of medical costs. Further technological advances and a more clear understanding and appreciation of the clinical and economic benefits of telecardiology, will likely increase sharply the use of remote IECD monitoring in upcoming years.
引用
收藏
页码:73 / 85
页数:12
相关论文
共 50 条
  • [21] The benefits of remote monitoring in long-term care for patients with implantable cardioverter-defibrillators
    Osmera, Ondrej
    Bulava, Alan
    NEUROENDOCRINOLOGY LETTERS, 2014, 35 : 40 - 48
  • [22] Automatic home monitoring of implantable cardioverter defibrillators
    Nielsen, Jens Cosedis
    Kottkamp, Hans
    Zabel, Markus
    Aliot, Etienne
    Kreutzer, Ulrich
    Bauer, Alexander
    Schuchert, Andreas
    Neuser, Hans
    Schumacher, Burghard
    Schmidinger, Herwig
    Stix, Guenter
    Clementy, Jacques
    Danilovic, Dejan
    Hindricks, Gerhard
    EUROPACE, 2008, 10 (06): : 729 - 735
  • [23] Remote monitoring of implantable cardioverter-defibrillators Problems and implications using a telemonitoring system
    Siebermair, J.
    Clauss, S.
    Martens, E.
    Schuessler, F.
    Oversohl, N.
    Haserueck, N.
    Estner, H. L.
    Kaeaeb, S.
    Wakili, R.
    HERZ, 2015, 40 : 110 - 118
  • [24] Findings of remote monitoring of implantable cardioverter defibrillators during the COVID-19 pandemic
    De Larochelliere, Hugo
    Champagne, Jean
    Sarrazin, Jean-Francois
    Steinberg, Christian
    Philippon, Francois
    Roy, Karine
    Molin, Franck
    O'Hara, Gilles
    Plourde, Benoit
    Blier, Louis
    Nault, Isabelle
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (11): : 1366 - 1372
  • [25] A prospective comparison of remote monitoring systems in implantable cardiac defibrillators: potential effects of frequency of transmissions
    de Ruvo, Ermenegildo
    Sciarra, Luigi
    Martino, Anna Maria
    Rebecchi, Marco
    Iulianella, Renzo Venanzio
    Sebastiani, Francesco
    Fagagnini, Alessandro
    Borrelli, Alessio
    Scara, Antonio
    Grieco, Domenico
    Tota, Claudia
    Stirpe, Federica
    Calo, Leonardo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 45 (01) : 81 - 90
  • [26] A prospective comparison of remote monitoring systems in implantable cardiac defibrillators: potential effects of frequency of transmissions
    Ermenegildo de Ruvo
    Luigi Sciarra
    Anna Maria Martino
    Marco Rebecchi
    Renzo Venanzio Iulianella
    Francesco Sebastiani
    Alessandro Fagagnini
    Alessio Borrelli
    Antonio Scarà
    Domenico Grieco
    Claudia Tota
    Federica Stirpe
    Leonardo Calò
    Journal of Interventional Cardiac Electrophysiology, 2016, 45 : 81 - 90
  • [27] Battery longevity of implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators: technical, clinical and economic aspects. An expert review paper from EHRA
    Boriani, Giuseppe
    Merino, Jose
    Wright, David J.
    Gadler, Fredrik
    Schaer, Beat
    Landolina, Maurizio
    EUROPACE, 2018, 20 (12): : 1882 - 1897
  • [28] Virtual clinics for follow-up of pacemakers and implantable cardioverter defibrillators in children
    Spentzou, Georgia
    Mayne, Kaitlin
    Fulton, Helen
    McLeod, Karen
    CARDIOLOGY IN THE YOUNG, 2019, 29 (10) : 1243 - 1247
  • [29] Prevalence of Cancelled Shock Therapy and Relationship to Shock Delivery in Recipients of Implantable Cardioverter-Defibrillators Assessed by Remote Monitoring
    Varma, Niraj
    Johnson, Mark A.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 : S42 - S46
  • [30] Delivering remote monitoring data to patients with implantable cardioverter-defibrillators: Does medium matter?
    Mirro, Michael
    Daley, Carly
    Wagner, Shauna
    Ghahari, Romisa Rohani
    Drouin, Michelle
    Toscos, Tammy
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (11): : 1526 - 1535