Decellularized ureter for tissue-engineered small-caliber vascular graft

被引:0
作者
Yuji Narita
Hideaki Kagami
Hiroshi Matsunuma
Yosuke Murase
Minoru Ueda
Yuichi Ueda
机构
[1] Nagoya University School of Medicine,Department of Clinical Cell Therapy and Tissue Engineering
[2] Nagoya University Graduate School of Medicine,Department of Cardiac Surgery
[3] The University of Tokyo,Division of Stem Cell Engineering, Institute of Medical Science
[4] Nagoya University Graduate School of Medicine,Department of Urology
[5] Nagoya University Graduate School of Medicine,Department of Cardiology
[6] Nagoya University Graduate School of Medicine,Department of Oral and Maxillofacial Surgery
来源
Journal of Artificial Organs | 2008年 / 11卷
关键词
Tissue engineering; Prosthesis; Small-diameter vascular graft;
D O I
暂无
中图分类号
学科分类号
摘要
Previous attempts to create small-caliber vascular prostheses have been limited. The aim of this study was to generate tissue-engineered small-diameter vascular grafts using decellularized ureters (DUs). Canine ureters were decellularized using one of four different chemical agents [Triton-X 100 (Tx), deoxycholate (DCA), trypsin, or sodium dodecyl sulfate (SDS)] and the histology, residual DNA contents, and immunogenicity of the resulting DUs were compared. The mechanical properties of the DUs were evaluated in terms of water permeability, burst strength, tensile strength, and compliance. Cultured canine endothelial cells (ECs) and myofibroblasts were seeded onto DUs and evaluated histologically. Canine carotid arteries were replaced with the EC-seeded DUs (n = 4). As controls, nonseeded DUs (n = 5) and PTFE prostheses (n = 4) were also used to replace carotid arteries. The degree of decelularization and the maintenance of the matrix were best in the Tx-treated DUs. Tx-treated and DCA-treated DUs had lower remnant DNA contents and immunogenicity than the others. The burst strength of the DUs was more than 500 mmHg and the maximum tensile strength of the DUs was not different to that of native ureters. DU compliance was similar to that of native carotid artery. The cell seeding test resulted in monolayered ECs and multilayered α-smooth muscle actin-positive cells on the DUs. The animal implantation model showed that the EC-seeded DUs were patent for at least 6 months after the operation, whereas the nonseeded DUs and PTFE grafts become occluded within a week. These results suggest that tissue-engineered DUs may be a potential alternative conduit for bypass surgery.
引用
收藏
页码:91 / 99
页数:8
相关论文
共 217 条
[1]  
Yada I.(2004)Thoracic and cardiovascular surgery in Japan during 2002: annual report by the Japanese Association for Thoracic Surgery Jpn J Thorac Cardiovasc Surg 52 491-508
[2]  
Wada H.(1983)Atherosclerosis and late closure of aortocoronary saphenous vein grafts: sequential angiographic studies at 2 weeks, 1 year, 5–7 years, and 10–12 years after surgery Circulation 68 1-7
[3]  
Fujita H.(2001)Tissue engineering of small-caliber vascular graft Eur J Cardiothorac Surg 20 164-169
[4]  
Campeau L.(2000)Current status of tissue engineering for cardiovascular structures J Artif Organs 3 102-106
[5]  
Enjalbert M.(2002)Ross operation with a tissue-engineered heart valve Ann Thorac Surg 74 1438-1442
[6]  
Lesperance J.(2003)Immunogenicity of decellularized cryopreserved allografts in pediatric cardiac surgery: comparison with standard cryopreserved allografts J Thorac Cardiovasc Surg 126 247-253
[7]  
Vaislic C.(2001)Transformation of nonvascular acellular tissue matrices into durable vascular conduits Ann Thorac Surg 71 S433-S436
[8]  
Grondin C.M.(2004)Cellular remodeling of depopulated bovine ureter used as an arteriovenous graft in a canine model J Am Coll Surg 198 778-783
[9]  
Bourassa M.G.(2006)Depopulated bovine ureteric xenograft for complex haemodialysis vascular access Eur J Vasc Endovasc Surg 32 181-186
[10]  
Hoerstrup S.P.(2007)Diagnostic imaging of, and radiologic intervention for, bovine ureter grafts used as a novel conduit for hemodialysis fistulas AJR Am J Roentgenol 188 641-646