摘要
An ultra-high resolution spectral domain optical coherence tomography (SD-OCT) was developed using a cost-effective supercontinuum laser. A spectral filter consists of a dispersive prism, a cylindrical lens and a right-angle prism was built to transmit the wavelengths in range 680–940 nm to the OCT system. The SD-OCT has achieved 1.9 μm axial resolution and the sensitivity was estimated to be 91.5 dB. A zero-crossing fringes matching method which maps the wavelengths to the pixel indices of the spectrometer was proposed for the OCT spectral calibration. A double sided foam tape as a static sample and the tip of a middle finger as a biological sample were measured by the OCT. The adhesive and the internal structure of the foam of the tape were successfully visualized in three dimensions. Sweat ducts was clearly observed in the OCT images at very high resolution. To the best of our knowledge, this is the first demonstration of ultra-high resolution visualization of sweat duct by OCT.
引用
收藏
页码:180 / 186
页数:6
相关论文
共 90 条
  • [1] Huang D(1991)Optical coherence tomography Science 254 1178-1181
  • [2] Swanson E(2015)Recent advances in clinical application of optical coherence tomography of human skin Clin. Cosmet. Investig. Dermatol. 8 345-963
  • [3] Lin C(1997)Optical coherence tomography of the human skin J. Am. Acad. Dermatol. 37 958-132
  • [4] Schuman J(2007)Application of optical non-invasive methods in skin physiology: a comparison of laser scanning microscopy and optical coherent tomography with histological analysis Skin Res. Technol. 13 119-1464
  • [5] Stinson W(2008)Optical coherence tomography imaging of bullous diseases J. Eur. Acad. Dermatol. Venereol. 22 1458-383
  • [6] Chang W(2012)Dynamic analysis for mental sweating of a group of eccrine sweat glands on a human fingertip by optical coherence tomography Skin Res. Technol. 18 378-894
  • [7] Hee M(2015)Morphology of human sweat ducts observed by optical coherence tomography and their frequency of resonance in the terahertz frequency region Sci. Rep. 5 9071-1246
  • [8] Flotte T(2003)Performance of fourier domain vs. time domain optical coherence tomography Opt. Express 11 889-747
  • [9] Gregory K(2004)Advances in broad bandwidth light sources for ultrahigh resolution optical coherence tomography Phys. Med. Biol. 49 1235-1014
  • [10] Puliafito C(2011)Molecular imaging true-colour spectroscopic optical coherence tomography Nat. Photonics 5 744-10664