Coronary artery calcium scoring with photon-counting CT: first in vivo human experience

被引:0
|
作者
Rolf Symons
Veit Sandfort
Marissa Mallek
Stefan Ulzheimer
Amir Pourmorteza
机构
[1] Radiology and Imaging Sciences - National Institutes of Health Clinical Center,Department of Imaging & Pathology
[2] University Hospitals Leuven,Department of Radiology and Imaging Sciences
[3] Siemens Healthcare GmbH,Department of Radiology and Imaging Sciences
[4] Emory University School of Medicine,undefined
[5] Winship Cancer Institute of Emory University,undefined
来源
The International Journal of Cardiovascular Imaging | 2019年 / 35卷
关键词
Coronary artery calcium score; Photon-counting CT; Radiation dose reduction;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the performance of photon-counting detector (PCD) computed tomography (CT) for coronary artery calcium (CAC) score imaging at standard and reduced radiation doses compared to conventional energy-integrating detector (EID) CT. A dedicated cardiac CT phantom, ten ex vivo human hearts, and ten asymptomatic volunteers underwent matched EID and PCD CT scans at different dose settings without ECG gating. CAC score, contrast, and contrast-to-noise ratio (CNR) were calculated in the cardiac CT phantom. CAC score accuracy and reproducibility was assessed in the ex vivo hearts. Standard radiation dose (120 kVp, reference mAs = 80) in vivo CAC scans were compared against dose-reduced CAC scans (75% dose reduction; reference mAs = 20) for image quality and CAC score reproducibility. Interstudy agreement was assessed by using intraclass correlation (ICC), linear regression, and Bland–Altman analysis with 95% confidence interval limits of agreement (LOA). Calcium-soft tissue contrast and CNR were significantly higher for the PCD CAC scans in the cardiac CT phantom (all P < 0.01). Ex vivo hearts: CAC score reproducibility was significantly higher for the PCD scans at the lowest dose setting (50 mAs) (P = 0.002); score accuracy was similar for both detector systems at all dose settings. In vivo scans: the agreement between standard dose and low dose CAC score was significantly better for the PCD than for the EID with narrower LOA in Bland–Altman analysis, linear regression slopes closer to 1 (0.96 vs. 0.84), and higher ICC values (0.98 vs. 0.93, respectively). Phantom and in vivo human studies showed PCD may significantly improve CAC score image quality and/or reduce CAC score radiation dose while maintaining diagnostic image quality.
引用
收藏
页码:733 / 739
页数:6
相关论文
共 50 条
  • [1] Coronary artery calcium scoring with photon-counting CT: first in vivo human experience
    Symons, Rolf
    Sandfort, Veit
    Mallek, Marissa
    Ulzheimer, Stefan
    Pourmorteza, Amir
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (04) : 733 - 739
  • [2] Combining photon-counting coronary CT and artificial intelligence to detect coronary artery stenosis
    Bluemke, David A.
    Nagpal, Prashant
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2025, 106 (02) : 45 - 46
  • [3] Abdominal applications of photon-counting CT
    Khanungwanitkul, Khanin
    Sliwicka, Olga
    Schwartz, Fides Regina
    BRITISH JOURNAL OF RADIOLOGY, 2024,
  • [4] Myocardial Radiomics Texture Features Associated with Increased Coronary Calcium Score-First Results of a Photon-Counting CT
    Ayx, Isabelle
    Tharmaseelan, Hishan
    Hertel, Alexander
    Noerenberg, Dominik
    Overhoff, Daniel
    Rotkopf, Lukas T.
    Riffel, Philipp
    Schoenberg, Stefan O.
    Froelich, Matthias F.
    DIAGNOSTICS, 2022, 12 (07)
  • [5] Photon-counting CT review
    Flohr, Thomas
    Petersilka, Martin
    Henning, Andre
    Ulzheimer, Stefan
    Ferda, Jiri
    Schmidt, Bernhard
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 79 : 126 - 136
  • [6] Pediatric Applications of Photon-Counting Detector CT
    Cao, Joseph
    Bache, Steve
    Schwartz, Fides R.
    Frush, Donald
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (04) : 580 - 589
  • [7] Saving Contrast Media in Coronary CT Angiography with Photon-Counting Detector CT
    Cundari, Giulia
    Deilmann, Philipp
    Mergen, Victor
    Ciric, Kristina
    Eberhard, Matthias
    Jungblut, Lisa
    Alkadhi, Hatem
    Higashigaito, Kai
    ACADEMIC RADIOLOGY, 2024, 31 (01) : 212 - 220
  • [8] Coronary artery disease detection using deep learning and ultrahigh-resolution photon-counting coronary CT angiography
    Brendel, Jan M.
    Walterspiel, Jonathan
    Hagen, Florian
    Kuebler, Jens
    Brendlin, Andreas S.
    Afat, Saif
    Paul, Jean-Francois
    Kuestner, Thomas
    Nikolaou, Konstantin
    Gawaz, Meinrad
    Greulich, Simon
    Krumm, Patrick
    Winkelmann, Moritz T.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2025, 106 (02) : 68 - 75
  • [9] Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck First In Vivo Human Results
    Symons, Rolf
    Reich, Daniel S.
    Bagheri, Mohammadhadi
    Cork, Tyler E.
    Krauss, Bernhard
    Ulzheimer, Stefan
    Kappler, Steffen
    Bluemke, David A.
    Pourmorteza, Amir
    INVESTIGATIVE RADIOLOGY, 2018, 53 (03) : 135 - 142
  • [10] Advanced Neuroimaging With Photon-Counting Detector CT
    Abel, Frederik
    Schubert, Tilman
    Winklhofer, Sebastian
    INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 472 - 481