Investigations on a solar humidification dehumidification desalination system equipped with various packing materials and multi-stage bubble column dehumidifier

被引:0
作者
Javed Sikandar Shaikh
Saleel Ismail
机构
[1] National Institute of Technology Calicut,Department of Mechanical Engineering
来源
Environmental Science and Pollution Research | 2023年 / 30卷
关键词
Humidification-dehumidification; Desalination; Bubble column Dehumidifier; Packing material; Solar desalination;
D O I
暂无
中图分类号
学科分类号
摘要
This work presents the theoretical and experimental investigation of a solar-powered humidification dehumidification desalination (HDD) system with different humidifier packing materials and a two-stage bubble column dehumidifier (BCD). Naturally available coconut shells (CS) and coconut shells with drilled holes (CSH) on the surface to improve water permeability were used as packing materials in the humidifier, and their performance was compared with that of commercial-type pall ring (PR) and raschig ring (RR) packings. An in-house developed numerical model of the HDD system in conjunction with a flat plate solar water collector was used in this study. Steady-state experimental results showed that CSH packing exhibited the highest volumetric mass transfer coefficient (0.00852 kg/s), resulting in maximum humidifier efficiency (96%) and freshwater yield (2.16 kg/hr), followed by PR (0.00841 kg/s, 94%, and 2.137 kg/hr), CS (0.00831 kg/s, 90%, and 2.127 kg/hr), and RR (0.0081 kg/s, 81%, and 2.087 kg/hr) at feedwater mass flow rate of 1.5 kg/min and humidifier inlet temperature of 75 ∘C\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$^\circ{\rm C}$$\end{document}. Furthermore, transient outdoor test results showed that using a two-stage configuration in a BCD increased the daily average effectiveness to 0.93, as against 0.79 for a single-stage BCD. Employing CSH instead of PR and RR packings in the humidifier reduced freshwater costs by 6.2% and 7.6%, respectively.
引用
收藏
页码:124286 / 124305
页数:19
相关论文
共 163 条
[1]  
Abad MZS(2022)Experimental evaluation of a solar-driven adsorption desalination system using solid adsorbent of silica gel and hydrogel Environ Sci Pollut Res 29 71217-71231
[2]  
Behshad Shafii M(2018)Performance evaluation of a humidification-dehumidification unit integrated with wick solar stills under different operating conditions Desalination 441 52-61
[3]  
Ebrahimpour B(2017)Experimental investigation of humidification-dehumidification desalination system with corrugated packing in the humidifier Desalination 410 19-29
[4]  
Abdullah AS(2006)Low temperature humidification dehumidification desalination process Energy Convers Manag 47 470-484
[5]  
Essa FA(2023)Improving the performance of a modified solar distiller with phase change material and parabolic trough collector Environ Sci Pollut Res 30 32710-32721
[6]  
Omara ZM(2021)A relative study on energy and exergy analysis between conventional single slope and novel stepped absorbable plate solar stills Environ Sci Pollut Res 28 57602-57618
[7]  
Bek MA(2016)Examination of a solar desalination system equipped with an air bubble column humidifier, evacuated tube collectors and thermosyphon heat pipes Desalination 397 30-37
[8]  
Ahmed HA(2003)Experimental validation of the distillation module of a desalination station using the SMCEC principle Renew Energy 28 2335-2354
[9]  
Ismail IM(2021)Economic analysis and experimental investigation of a direct absorption solar humidification-dehumidification system for decentralized water production Sustain Energy Technol Assess 46 101306-419
[10]  
Saleh WF(2010)Desalination based on humidification-dehumidification by air bubbles passing through brackish water Chem Eng J 165 413-3703