Applying Human Factors to the Design of Medical Equipment: Patient-Controlled Analgesia

被引:0
作者
Laura Lin
Racquel Isla
Karine Doniz
Heather Harkness
Kim J. Vicente
D. John Doyle
机构
[1] University of Toronto,Cognitive Engineering Laboratory, Department of Mechanical & Industrial Engineering
[2] University of Toronto,Institute of Biomedical Engineering
[3] University of Toronto,Department of Anaesthesia
来源
Journal of Clinical Monitoring and Computing | 1998年 / 14卷
关键词
Medical equipment; interface design; human factors; task analysis; patient-controlled analgesia; human-computer interaction;
D O I
暂无
中图分类号
学科分类号
摘要
Objective. Medical instruments commonly have poorly designed user interfaces that promote human errors with life-threatening consequences. The primary hypothesis of this study was that a specific user interface could be made safer and more efficient if redesigned using human factors techniques and principles. Methods. The user interface of a commercially available patient-controlled analgesia (PCA) pump, the Abbott Lifecare 4100 PCA Plus II infuser, was evaluated using a cognitive task analysis of bench tests and field observations. Based on this analysis, the user interface was redesigned. Important elements of the new design include a dialog structure with fewer steps, a dialog overview showing the user's location in the programming sequence, better command feedback, easier error recovery, and clearer labels and messages. The changes were evaluated by comparing a computer prototype of the new interface with a computer simulation of the old one. Twelve student nurses performed six programming tasks with each interface. Task completion time, number of errors, and subjective mental workload were collected for each trial. Results. The results showed significantly faster programming times (F(1,11) = 6.85, P < 0.025), lower mental workload ratings (χ2(1) = 4.45, p < 0.025, one-tailed), and fewer errors (χ2(1) = 3.33, p < 0.05, one-tailed) with the new interface. Conclusion. Adopting a human factors approach to redesigning the PCA interface led to significantly faster, easier, and more reliable performance. These findings have important implications for improving the design of other computer-based medical equipment.
引用
收藏
页码:253 / 263
页数:10
相关论文
共 22 条
[1]  
Leape LL(1994)Error in medicine J Am Med Assoc 272 1851-1857
[2]  
White PF(1987)Mishaps with patient-controlled analgesia Anesthesiology 66 81-143
[3]  
Smythe M(1992)Patient-controlled analgesia: A review Pharmacotherapy 12 132-606
[4]  
Cohen MR(1993)Preventing errors associated with P.C.A. pumps Nursing 23 17-453
[5]  
Vicente KJ(1992)Ecological interface design: Theoretical foundations IEEE Transactions on Systems, Man, and Cybernetics SMC-22 589-1235
[6]  
Rasmussen J(1992)Patient and nurse evaluation of patient-controlled analgesia delivery systems for postoperative pain management J Pain Symptom Management 7 443-200
[7]  
Sawaki Y(1986)Patient-controlled analgesia: Experience of two new machines Anaesthesia 41 1230-226
[8]  
Parker RK(1994)A system for standardized evaluation of patient-controlled analgesia devices: Design, construction, and engineering aspects J Clin Monit 10 194-undefined
[9]  
White PF(1991)Evaluating the human engineering of microprocessor controlled operating room devices J Clin Monit 7 217-undefined
[10]  
Owen H(undefined)undefined undefined undefined undefined-undefined