Attosecond nonlinear optics using gigawatt-scale isolated attosecond pulses

被引:0
作者
Eiji J. Takahashi
Pengfei Lan
Oliver D. Mücke
Yasuo Nabekawa
Katsumi Midorikawa
机构
[1] Extreme Photonics Research Group,Ultrafast Optics and X
[2] RIKEN Center for Advanced Photonics,Rays Division
[3] Center for Free-Electron Laser Science,undefined
[4] Deutsches Elektronen-Synchrotron DESY,undefined
[5] The Hamburg Center for Ultrafast Imaging,undefined
[6] Luruper Chaussee 149,undefined
[7] Present address: School of Physics,undefined
[8] Huazhong University of Science and Technology,undefined
[9] Wuhan 430074,undefined
[10] China,undefined
来源
Nature Communications | / 4卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
High-energy isolated attosecond pulses required for the most intriguing nonlinear attosecond experiments as well as for attosecond-pump/attosecond-probe spectroscopy are still lacking at present. Here we propose and demonstrate a robust generation method of intense isolated attosecond pulses, which enable us to perform a nonlinear attosecond optics experiment. By combining a two-colour field synthesis and an energy-scaling method of high-order harmonic generation, the maximum pulse energy of the isolated attosecond pulse reaches as high as 1.3 μJ. The generated pulse with a duration of 500 as, as characterized by a nonlinear autocorrelation measurement, is the shortest and highest-energy pulse ever with the ability to induce nonlinear phenomena. The peak power of our tabletop light source reaches 2.6 GW, which even surpasses that of an extreme-ultraviolet free-electron laser.
引用
收藏
相关论文
共 97 条
[1]  
Hentschel M(2001)Attosecond metrology Nature 414 509-513
[2]  
Krausz F(2009)Attosecond physics Rev. Mod. Phys. 81 163-234
[3]  
Ivanov M(1993)Above threshold ionization beyond the high harmonic cutoff Phys. Rev. Lett. 70 1599-1602
[4]  
Schafer KJ(1993)Plasma perspective on strong-field multiphoton ionization Phys. Rev. Lett. 71 1994-1997
[5]  
Yang B(2002)Generation of highly coherent submicrojoule soft x rays by high-order harmonics Phys. Rev. A 66 021802(R)-1922
[6]  
DiMauro LF(2002)Generation of 10-μJ coherent extreme-ultraviolet light by use of high-order harmonics Opt. Lett. 27 1920-271
[7]  
Kulander KC(2003)Direct observation of attosecond light bunching Nature 426 267-324
[8]  
Corkum PB(2006)Interferometric autocorrelation of an attosecond pulse train in the single-cycle regime Phys. Rev. Lett. 97 153904-1617
[9]  
Takahashi EJ(2010)Single-shot femtosecond X-ray holography using extended references Phys. Rev. Lett. 105 093901-663
[10]  
Nabekawa Y(2011)Intense coherent light in extreme ultraviolet region by free electron laser seeded with 13th harmonic of Ti:sapphire laser Opt. Express 19 317-879