3D peripheral subtraction MRA using flow-spoiled ECG-triggered balanced SSFP

被引:0
|
作者
Zhaoyang Fan
Xiaoming Bi
John Sheehan
James Carr
Jerecic Renate
Debiao Li
机构
[1] Northwestern University,
[2] Siemens Medical Solutions,undefined
关键词
Peripheral Arterial Disease; Nephrogenic Systemic Fibrosis; Peripheral Arterial Disease Patient; Vessel Wall Imaging; Venous Contamination;
D O I
10.1186/1532-429X-11-S1-P288
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 33 条
  • [21] Vessel-wall imaging and quantification of flow-mediated dilation using water-selective 3D SSFP-echo
    Langham, Michael C.
    Li, Cheng
    Englund, Erin K.
    Chirico, Erica N.
    Mohler, Emile R., III
    Floyd, Thomas F.
    Wehrli, Felix W.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [22] Pilot Study of Improved Lesion Characterization in Breast MRI Using a 3D Radial Balanced SSFP Technique With Isotropic Resolution and Efficient Fat-Water Separation
    Moran, Catherine J.
    Kelcz, Frederick
    Jung, Youngkyoo
    Brodsky, Ethan K.
    Fain, Sean B.
    Block, Walter F.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (01) : 135 - 144
  • [23] Peripheral angiography in diabetics with critical ischemia: Can triggered 2D TOF or subtracted 3D gadolinium enhanced MR imaging angiography replace selective digital subtraction angiography?
    Brophy, DP
    Saouaf, R
    Hartnell, GG
    McEniff, NJ
    Wheeler, HG
    Edelman, RR
    RADIOLOGY, 1997, 205 : 1355 - 1355
  • [24] Magnetic resonance angiography (MRA) of internal carotid arteries: Breath-hold Gd-enhanced 3D FISP versus unenhanced 2D or 3D TOF techniques, using digital subtraction angiography as a gold standard
    Zandrino, F
    Sardanelli, F
    Parodi, R
    Delfino, L
    De Caro, G
    RADIOLOGY, 1998, 209P : 427 - 427
  • [25] Pre-surgical evaluation of ICA-stenosis using 3D power Doppler, 3D color coded Doppler sonography, 3D B-flow and contrast enhanced B-flow in correlation to CTA/MRA: First clinical results
    Pfister, K.
    Rennert, J.
    Greiner, B.
    Jung, W.
    Stehr, A.
    Goessmann, H.
    Menzel, C.
    Zorger, N.
    Prantl, L.
    Feuerbach, S.
    Kasprzak, P.
    Jung, E. M.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 41 (02) : 103 - 116
  • [26] Reduction of flow-related signal void in flow-compensated 3D TOF MRA by minimizing the effective echo time using variable TE
    Jeong, E
    Parker, DL
    Goodrich, KC
    RADIOLOGY, 2001, 221 : 598 - 598
  • [27] Fast T1 mapping determined using incomplete inversion recovery look-locker 3D balanced SSFP acquisition and a simple two-parameter model fit
    Gai, Neville D.
    Butman, John A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (06) : 1437 - 1444
  • [28] Exploring extreme rainfall-triggered landslides using 3D unsaturated flow, antecedent moisture and spatially distributed soil depth
    Marotti, Jessica C.
    Gomes, Guilherme J. C.
    Velloso, Raquel Q.
    Vargas Junior, Euripedes A.
    Nunes, Rafael S.
    Fernandes, Nelson F.
    CATENA, 2023, 229
  • [29] 3D numerical modeling using smoothed particle hydrodynamics of flow-like landslide propagation triggered by the 2008 Wenchuan earthquake
    Dai, Zili
    Huang, Yu
    Cheng, Hualin
    Xu, Qiang
    ENGINEERING GEOLOGY, 2014, 180 : 21 - 33
  • [30] Free-breathing non-contrast-enhanced flow-independent MR angiography using magnetization-prepared 3D non-balanced dual-echo Dixon method: A feasibility study at 3 Tesla
    Yoneyama, Masami
    Zhang, Shuo
    Hu, Houchun Harry
    Chong, Le Roy
    Bardo, Dianna
    Miller, Jeffrey H.
    Toyonari, Nobuyuki
    Katahira, Kazuhiro
    Katsumata, Yasutomo
    Pokorney, Amber
    Ng, Chian Keat
    Kouwenhoven, Marc
    Van Cauteren, Marc
    MAGNETIC RESONANCE IMAGING, 2019, 63 : 137 - 146