共 50 条
Resolution of salbutamol enantiomers in human urine by reversed-phase high performance liquid chromatography after derivatization with (S)-(-)-α-methylbenzyl isocyanate
被引:0
作者:
Kyeong Ho Kim
Tae Kyun Kim
Young Hee Kwon
Young Taek Sohn
机构:
[1] Kangwon National University,College of Pharmacy
[2] Choseon Pharm. & Trading Co.,Institute of Life Science Research
[3] Seoul National University Hospital,Department of Pharmacy
[4] Duksung Women's University,College of Pharmacy
来源:
Archives of Pharmacal Research
|
1997年
/
20卷
关键词:
Chiral separation;
HPLC;
Chiral derivatizing reagent;
Salbutamol;
Enantiomer;
(S)-(−)-α-methylbenzyl isocyanate;
D O I:
暂无
中图分类号:
学科分类号:
摘要:
A stereospecific HPLC method has been developed for the resolution of the enantiomers of salbutamol in human urine. After solid-phase extraction and derivatization with (S)-(-)-α-methylbenzyl isocyanate, the diastereomeric derivatives were resolved (Rs=1.59) on 5 μm octadecylsilan column using 47% methanol as a mobile phase with fluorescence detection. The detection limit of each enantiomer was 10 ng/ml (S/N=3).
引用
收藏
页码:486 / 490
页数:4
相关论文
共 50 条