Effects of porcelain veneering methods on conformity of the marginal and internal fit of three-unit zirconia framework

被引:0
|
作者
Shohei Suzuki
Kazuhiko Ueda
Kurt Erdelt
Fumihiko Watanabe
Jan-Frederik Güth
机构
[1] The Nippon Dental University,Department of Crown and Bridge Prosthodontics, School of Life Dentistry at Niigata
[2] University Hospital,Department of Prosthetic Dentistry
[3] LMU Munich,undefined
来源
Odontology | 2021年 / 109卷
关键词
CAD/CAM; Zirconia; Fitness; Veneering; Fixed dental prosthesis;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study is to investigate the effects of porcelain veneering methods on the marginal and internal fit of a three-unit zirconia framework. A zirconia master model, in which the lower-left second premolar and the second left molar were used as the abutment, was obtained using an intraoral scanner. Based on the data, three-unit zirconia frameworks for fabricating all-ceramic bridges were designed and milled (FW group). Two types of all-ceramic bridge were fabricated by veneering porcelain onto these frameworks using the press-over technique (P group) and the layering technique (L group). The replica technique was used to measure the gap size between the abutments and the bridges. Measurements were taken in the marginal opening area (MO), chamfer area (CH), axial area (AX), and occlusal area (OC). Statistical analysis was performed using the Mann–Whitney U-test. There was no significant difference in MO and CH between the P and L groups. However, in AX, the L group had a significantly larger gap size than that of the P group (p = 0.003). In addition, compared with the FW group, the P group showed a significantly larger gap size in MO (p < 0.000), CH (p = 0.008), and OC (p < 0.000). These results indicate that the gap size increased after porcelain veneering using the press-over and layering techniques. In addition, the all-ceramic bridges fabricated using the press-over and layering techniques had approximately equal gap sizes in MO.
引用
收藏
页码:719 / 728
页数:9
相关论文
共 33 条
  • [31] Comparison of marginal and internal fit of 5-unit zirconia fixed dental prostheses fabricated with CAD/CAM technology using direct and indirect digital scans
    Uluc, Irem Gokce
    Guncu, Mustafa Baris
    Aktas, Guliz
    Turkyilmaz, Ilser
    JOURNAL OF DENTAL SCIENCES, 2022, 17 (01) : 63 - 69
  • [32] Marginal and internal fit of five-unit zirconia-based fixed dental prostheses fabricated with digital scans and conventional impressions: A comparative in vitro study
    Bandiaky, Octave Nadile
    Clouet, Roselyne
    Le Bars, Pierre
    Soueidan, Assem
    Le Guehennec, Laurent
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 846 - 853
  • [33] Hardware complications and failure of three-unit zirconia-based and porcelain-fused-metal implant-supported fixed dental prostheses: a retrospective cohort study with up to 8years
    Shi, Jun-Yu
    Zhang, Xiao-Meng
    Qiao, Shi-Chong
    Qian, Shu-Jiao
    Mo, Jia-Ji
    Lai, Hong-Chang