Cardiac imaging using 256-detector row four-dimensional CT: Preliminary clinical report

被引:43
作者
Kido T. [1 ]
Kurata A. [2 ]
Higashino H. [1 ]
Sugawara Y. [1 ]
Okayama H. [2 ]
Higaki J. [2 ]
Anno H. [3 ]
Katada K. [3 ]
Mori S. [4 ]
Tanada S. [4 ]
Endo M. [4 ]
Mochizuki T. [1 ]
机构
[1] Department of Radiology, Ehime University, School of Medicine, Shitsukawa
[2] Department of Cardiology, Ehime University, School of Medicine, Shitsukawa, Toon
[3] Department of Radiology, Fujita Health University, Toyoake
[4] Department of Medical Physics, National Institute of Radiological Sciences, Chiba
来源
Radiation Medicine | 2007年 / 25卷 / 1期
关键词
Cardiac function; Coronary artery; Multislice CT;
D O I
10.1007/s11604-006-0097-z
中图分类号
学科分类号
摘要
Purpose. Along with the increase of detector rows on the z-axis and a faster gantry rotation speed, the spatial and temporal resolutions of the multislice computed tomography (CT) have been improved for noninvasive coronary artery imaging. We investigated the feasibility of the second specification prototype 256-detector row four-dimensional CT for assessing coronary artery and cardiac function. Materials and methods. The subjects were five patients with coronary artery disease. Contrast medium (40-60 ml) was intravenously administered at the rate of 3-4 ml/s. The patient's whole heart was scanned for 1.5 s to cover at least one cardiac cycle during breathholding without electrocardiographic gating. Parameters used were 0.5 mm slice thickness, 0.5 s/rotation, 120 Kv, and 350 mA, with a half-scan reconstruction algorithm (temporal resolution 250 ms). Twenty-six transaxial datasets were reconstructed at intervals of 50 ms. Results. The assessability of the coronary arteries in AHA segments 1, 2, 3, 5, 6, 7, 9, and 11 was visually evaluated, resulting in 29 of 32 (90.9%) segments being assessable. Functional assessment was also performed using animated movies without banding artifacts in all cases. Conclusions. The 256-detector row four-dimensional CT can assess the coronary artery and cardiac function using data during 1.5 s without banding artifacts. © Japan Radiological Society 2007.
引用
收藏
页码:38 / 44
页数:6
相关论文
共 21 条
  • [1] Nieman K., Oudkerk M., Rensing B.J., van Ooijen P., Munne A., van Geuns R.J., Et al., Coronary angiography with multi-slice computed tomography, Lancet, 357, pp. 599-603, (2001)
  • [2] Sato Y., Matsumoto N., Kato M., Inoue F., Horie T., Kusama J., Et al., Noninvasive assessment of coronary artery disease by multislice spiral computed tomography using a new retrospetively ECG-gated image reconstruction technique, Circ J, 67, pp. 401-405, (2003)
  • [3] Kuettner A., Trabold T., Schroeder S., Feyer A., Beck T., Brueckner A., Et al., Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: Initial clinical results, J Am Coll Cardiol, 44, pp. 1238-1240, (2004)
  • [4] Mollet N.R., Cademartiri F., Nieman K., Saia F., Lemos P.A., McFadden E.P., Et al., Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris, J Am Coll Cardiol, 43, pp. 2265-2270, (2004)
  • [5] Leber A.W., Knez A., von Ziegler F., Becker A., Nikolaou K., Paul S., Et al., Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: A comparative study with quantitative coronary angiography and intravascular ultrasound, J Am Coll Cardiol, 46, pp. 147-154, (2005)
  • [6] Raff G.L., Gallagher M.J., O'Neill W.W., Goldstein J.A., Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography, J Am Coll Cardiol, 46, pp. 552-557, (2005)
  • [7] Mochizuki T., Murase K., Higashino H., Higashino H., Koyama Y., Azemoto S., Et al., Two- and three-dimensional CT ventriculography: A new application of helical CT, AJR Am J Roentgenol, 174, pp. 203-208, (2000)
  • [8] Kopp A.F., Heuschmid M., Reimann A., Kuettner A., Heuschnid M., Kopp A.F., Et al., Evaluation of cardiac function and myocardial viability with 16- and 64-slice multidetector computed tomography, Eur Radiol, 15, SUPPL. 4, (2005)
  • [9] Higashino H., Mochizuki T., Haraikawa T., Kurata A., Kido T., Nakata S., Et al., Image fusion of coronary tree and regional cardiac function image using multislice computed tomography, Circ J, 70, pp. 105-109, (2006)
  • [10] Abbara S., Cury R.C., Nieman K., Reddy V., Moselewski F., Schmidt S., Et al., Noninvasive evaluation of cardiac veins with 16-MDCT angiography, AJR Am J Roentgenol, 185, pp. 1001-1006, (2005)