The optimization of coal on-line analysis system based on signal-to-noise ratio evaluation

被引:0
作者
JiaTong Li
WenBao Jia
DaQian Hei
PingKun Cai
Can Cheng
Yajun Tang
机构
[1] Nanjing University of Aeronautics and Astronautics,Department of Nuclear Science and Engineering, College of Materials Science and Engineering
[2] Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions,undefined
来源
Journal of Radioanalytical and Nuclear Chemistry | 2018年 / 318卷
关键词
Signal-to-noise ratio (SNR); MCNP simulation; PGNAA; System optimization;
D O I
暂无
中图分类号
学科分类号
摘要
In the present study, the coal on-line analysis system is optimized, and the signal-to-noise ratio (SNR) is quantified and set as the evaluation criterion for device optimization. 3 cm lead with 3 cm polyethylene is set as moderator, and 13 cm lead is for a better shielding. Besides, the neutron generator is set at the center of device, and 72 cm is set as the better distance of axis between neutron generator and detector. Finally, by comparing with the previous experimental results, the Mean Absolute Percentage Error of element with the value less than 1% is improved after device optimization by SNR evaluation.
引用
收藏
页码:1279 / 1286
页数:7
相关论文
共 87 条
  • [1] Naqvi AA(2013)Optimization of a prompt gamma setup for analysis of environmental samples J Radioannal Nucl Chem undefined undefined-undefined
  • [2] Al-Matouq FA(2011)Estimation of minimum detectable concentration of chlorine in the blast furnace slag cement concrete Nucl Instrum Methods Phys Res undefined undefined-undefined
  • [3] Khiari FZ(2005)Performance of the vertical optical filter for the NG-3 30 m SANS instrument at the National Institute of Standards and Technology’s center for neutron research Rev Sci Instrum undefined undefined-undefined
  • [4] Khateeb-ur-Rehman Gondal MA(2011)A compact neutron beam generator system designed for prompt gamma nuclear activation analysis Appl Radiat Isot undefined undefined-undefined
  • [5] Isab AA(2016)Source substitution and optimization of CBX Prog Nucl Energy undefined undefined-undefined
  • [6] Naqvi AA(2015) PGNAA analyzer in Kangan cement plant Nucl Instrum Methods Phys Res undefined undefined-undefined
  • [7] Maslehuddin M(2009)In-beam activation analysis facility at MLZ Garching Radiat Phys Chem undefined undefined-undefined
  • [8] Garwan MA(2000)Status of the Monte Carlo library least-squares (MCLLS) approach for non-linear radiation analyzer problems Appl Radiat Isot undefined undefined-undefined
  • [9] Nagadi MM(2007)A feasibility study of a coincidence counting approach for PGNAA applications Nucl Instrum Methods Phys Res undefined undefined-undefined
  • [10] Al-Amoudi OSB(2007)The Monte Carlo code CEARCPG for coincidence prompt gamma-ray neutron activation analysis Trans Am Nucl Soc undefined undefined-undefined