320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose

被引:0
|
作者
Chuanchen Zhang
Zhaoqi Zhang
Zixu Yan
Lei Xu
Wei Yu
Rui Wang
机构
[1] Capital Medical University,Department of Radiology, Beijing Anzhen Hospital
来源
The International Journal of Cardiovascular Imaging | 2011年 / 27卷
关键词
320-Row computed tomography; Contrast material; Coronary angiography; Coronary vessels; Radiation dosage;
D O I
暂无
中图分类号
学科分类号
摘要
To prospectively evaluate image quality parameters, contrast volume and radiation dose at the 100-kilovolt (kV) setting during coronary computed tomographic angiography (CCTA) on a 320-row computed tomography scanner. We enrolled 107 consecutive patients with a heart rate <65 beats per minute (bpm) undergoing prospective electrocardiogram (ECG)-triggered CCTA. Forty patients with a body mass index (BMI) <25 kg/m2 were scanned using 100-kV tube voltage settings, while 67 patients were scanned using 120-kV protocols. Image quality was assessed by two readers unaware of patient information and scan parameters. Attenuation in the aorta and perivascular fat tissue and image noise were measured. Contrast-to-noise ratios (CNRs) and contrast material volumes were calculated. The effective radiation doses were estimated using a chest conversion coefficient (0.017). Diagnostic image quality was achieved in 98.2% of coronary segments with 100-kV CCTA and 98.6% of coronary segments with 120-kV CCTA, with no significant differences in image quality scores for each coronary segment. Vessel attenuation, image noise, and CNR were not significantly different between the 100- and 120-kV protocols. Mean contrast injection rate and mean material volume were significantly lower for the 100-kV CCTA (4.35 ± 0.28 ml/s and 53.13 ± 3.77 ml, respectively) than for the 120-kV CCTA (5.16 ± 0.21 ml/s and 62.40 ± 3.66 ml respectively; P < 0.001). The effective radiation dose was 2.12 ± 0.19 mSv for 100-kV CCTA, a reduction of 54% compared to 4.61 ± 0.82 mSv for 120-kV CCTA. A 100-kV CCTA can be implemented in patients with a BMI < 25 kg/m2. The 100-kV setting allows significant reductions in contrast material volume and effective radiation dose while maintaining adequate diagnostic image quality.
引用
收藏
页码:1059 / 1068
页数:9
相关论文
共 36 条
  • [21] High-strength deep learning image reconstruction in coronary CT angiography at 70-kVp tube voltage significantly improves image quality and reduces both radiation and contrast doses
    Wanjiang Li
    Kaiyue Diao
    Yuting Wen
    Tao Shuai
    Yongchun You
    Jin Zhao
    Kai Liao
    Chunyan Lu
    Jianqun Yu
    Yong He
    Zhenlin Li
    European Radiology, 2022, 32 : 2912 - 2920
  • [22] ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality
    Hong, C
    Becker, CR
    Huber, A
    Schoepf, UJ
    Ohnesorge, B
    Knez, A
    Brüning, R
    Reiser, MF
    RADIOLOGY, 2001, 220 (03) : 712 - 717
  • [23] Performance evaluation of using shorter contrast injection and 70 kVp with deep learning image reconstruction for reduced contrast medium dose and radiation dose in coronary CT angiography for children: a pilot study
    Sun, Jihang
    Li, Haoyan
    Li, Jianying
    Cao, Yongli
    Zhou, Zuofu
    Li, Michelle
    Peng, Yun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (09) : 4162 - 4171
  • [24] Influence of Contrast Agent Injection Scheme Customized by Dual-Source CT Based on Automatic Tube Voltage Technology on Image Quality and Radiation Dose of Coronary Artery Imaging
    He, Weiling
    Chen, Xin
    Hu, Rui
    Sun, Wenjie
    Tan, Weili
    FRONTIERS IN SURGERY, 2022, 9
  • [25] The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography Effects on image quality and radiation dose
    Feng, Cui
    Zhu, Di
    Zou, Xianlun
    Li, Anqin
    Hu, Xuemei
    Li, Zhen
    Hu, Daoyu
    MEDICINE, 2018, 97 (12)
  • [26] CT Angiography of the Head-and-Neck Vessels Acquired with Low Tube Voltage, Low Iodine, and Iterative Image Reconstruction: Clinical Evaluation of Radiation Dose and Image Quality
    Zhang, Wei-lan
    Li, Min
    Zhang, Bo
    Geng, Hai-yang
    Liang, Yin-qiang
    Xu, Ke
    Li, Song-bai
    PLOS ONE, 2013, 8 (12):
  • [27] Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison
    Krazinski, Aleksander W.
    Meinel, Felix G.
    Schoepf, U. Joseph
    Silverman, Justin R.
    Canstein, Christian
    De Cecco, Carlo N.
    Geyer, Lucas L.
    EUROPEAN RADIOLOGY, 2014, 24 (11) : 2677 - 2684
  • [28] Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
    Zhuang, Y.
    Huang, W.
    Shi, Y.
    Bo, G.
    Lu, D.
    Zhang, J.
    Kong, D.
    Shit, Y.
    Wang, B.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (02): : 225 - 233
  • [29] Improvement of Image Quality at Low-Radiation Dose and Low-Contrast Material Dose Abdominal CT in Patients With Cirrhosis: Intraindividual Comparison of Low Tube Voltage With Iterative Reconstruction Algorithm and Standard Tube Voltage
    Namimoto, Tomohiro
    Oda, Seitaro
    Utsunomiya, Daisuke
    Shimonobo, Toshiaki
    Morita, Sosuke
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (04) : 495 - 501
  • [30] Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality
    Zhang, Xiuli
    Li, Shaodong
    Liu, Wenlou
    Huang, Ning
    Li, Jingjing
    Cheng, Li
    Xu, Kai
    MEDICINE, 2016, 95 (26)