320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose

被引:0
|
作者
Chuanchen Zhang
Zhaoqi Zhang
Zixu Yan
Lei Xu
Wei Yu
Rui Wang
机构
[1] Capital Medical University,Department of Radiology, Beijing Anzhen Hospital
来源
The International Journal of Cardiovascular Imaging | 2011年 / 27卷
关键词
320-Row computed tomography; Contrast material; Coronary angiography; Coronary vessels; Radiation dosage;
D O I
暂无
中图分类号
学科分类号
摘要
To prospectively evaluate image quality parameters, contrast volume and radiation dose at the 100-kilovolt (kV) setting during coronary computed tomographic angiography (CCTA) on a 320-row computed tomography scanner. We enrolled 107 consecutive patients with a heart rate <65 beats per minute (bpm) undergoing prospective electrocardiogram (ECG)-triggered CCTA. Forty patients with a body mass index (BMI) <25 kg/m2 were scanned using 100-kV tube voltage settings, while 67 patients were scanned using 120-kV protocols. Image quality was assessed by two readers unaware of patient information and scan parameters. Attenuation in the aorta and perivascular fat tissue and image noise were measured. Contrast-to-noise ratios (CNRs) and contrast material volumes were calculated. The effective radiation doses were estimated using a chest conversion coefficient (0.017). Diagnostic image quality was achieved in 98.2% of coronary segments with 100-kV CCTA and 98.6% of coronary segments with 120-kV CCTA, with no significant differences in image quality scores for each coronary segment. Vessel attenuation, image noise, and CNR were not significantly different between the 100- and 120-kV protocols. Mean contrast injection rate and mean material volume were significantly lower for the 100-kV CCTA (4.35 ± 0.28 ml/s and 53.13 ± 3.77 ml, respectively) than for the 120-kV CCTA (5.16 ± 0.21 ml/s and 62.40 ± 3.66 ml respectively; P < 0.001). The effective radiation dose was 2.12 ± 0.19 mSv for 100-kV CCTA, a reduction of 54% compared to 4.61 ± 0.82 mSv for 120-kV CCTA. A 100-kV CCTA can be implemented in patients with a BMI < 25 kg/m2. The 100-kV setting allows significant reductions in contrast material volume and effective radiation dose while maintaining adequate diagnostic image quality.
引用
收藏
页码:1059 / 1068
页数:9
相关论文
共 36 条
  • [1] 320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose
    Zhang, Chuanchen
    Zhang, Zhaoqi
    Yan, Zixu
    Xu, Lei
    Yu, Wei
    Wang, Rui
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) : 1059 - 1068
  • [2] Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy
    Kim, Rihyeon
    Park, Eun-Ah
    Lee, Whal
    Chung, Jin Wook
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 3802 - 3810
  • [3] Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy
    Rihyeon Kim
    Eun-Ah Park
    Whal Lee
    Jin Wook Chung
    European Radiology, 2016, 26 : 3802 - 3810
  • [4] Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose
    Chien-Ming Chen
    Sung-Yu Chu
    Ming-Yi Hsu
    Ying-Lan Liao
    Hui-Yu Tsai
    European Radiology, 2014, 24 : 460 - 468
  • [5] Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose
    Chen, Chien-Ming
    Chu, Sung-Yu
    Hsu, Ming-Yi
    Liao, Ying-Lan
    Tsai, Hui-Yu
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 460 - 468
  • [6] Comparison of position, morphology and calcification of Coronary Plaque with 320-row dynamic volume CT (DVCT) and coronary angiography (CAG)
    Li, Xiaoyan
    Zhang, Guoming
    Zhang, Hongming
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2014, 30 (04) : 824 - 829
  • [7] Effect of saline flush on enhancement of proximal and distal segments using 320-row coronary CT angiography
    Tomizawa, Nobuo
    Suzuki, Fumio
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) : 1255 - 1259
  • [8] Effect of Automatic Tube Current Modulation on Radiation Dose and Image Quality for Low Tube Voltage Multidetector Row CT Angiography: Phantom Study
    Schindera, Sebastian T.
    Nelson, Rendon C.
    Yoshizumi, Terry
    Toncheva, Greta
    Nguyen, Giao
    DeLong, David M.
    Szucs-Farkas, Zsolt
    ACADEMIC RADIOLOGY, 2009, 16 (08) : 997 - 1002
  • [9] Image quality and radiation doses of volumetric 320-row computed tomography angiography with prospective electrocardiogram-gating in the assessment of coronary arteries in neonates and infants
    Roik, Danuta
    Kucinska, Beata
    Roik, Marek
    Werner, Bozena
    KARDIOLOGIA POLSKA, 2022, 80 (05) : 567 - 574
  • [10] Evaluation of image quality and radiation dose in low tube voltage coronary computed tomography angiography
    Mousavi-Gazafroudi, Seyedeh Shokoofeh
    Sajjadieh-Khajouei, Amirreza
    Moradi, Maryam
    Mousavi-Gazafroudi, Seyedeh Shabnam
    Yadegarfar, Ghasem
    Tavakoli, Mohammad Bagher
    ARYA ATHEROSCLEROSIS, 2019, 15 (05) : 205 - 210