The utility and precision of analogue and digital preoperative planning for total hip arthroplasty

被引:0
作者
Alejandro González Della Valle
Fernando Comba
Nicole Taveras
Eduardo A. Salvati
机构
[1] Weill Medical College of Cornell University,Hospital for Special Surgery
[2] Hospital Italiano de Buenos Aires,Institute of Orthopaedics “Carlos E. Ottolenghi”
来源
International Orthopaedics | 2008年 / 32卷
关键词
Stem Size; Digital Plan; Prosthetic Head; Digital Templating; Preoperative Templating;
D O I
暂无
中图分类号
学科分类号
摘要
We prospectively compared the utility and precision of preoperative templating performed in printed films (analogue) with that performed on digital radiographs (digital) in 69 patients undergoing primary total hip replacement. Five patients were excluded when misplacement of the marker resulted in a magnification error greater that 10%; in the remaining patients (64 hips), the cup size was within ± one size in 62 (97%) of the analogue and 52 (81%) of the digital (p = 0.01) plans. The stem size was within ± one size in 63 (98%) of the analogue and 60 (94%) of the digital (p = 0.39) plans. The distance from the proximal corner of the lesser trochanter to the center of the prosthetic head (LTCD) in the analogue differed by 5 mm or more from the digital plan in nine cases (14%). Analogue preoperative planning yielded more predictable results than digital planning, particularly in terms of acetabular component size and LTCD that dictates limb lengthening-shortening. The sources of error were not clearly explained by variations in magnification. Inconsistent positioning of the magnification marker may jeopardise the safe implementation of digital templating.
引用
收藏
页码:289 / 294
页数:5
相关论文
共 50 条
  • [41] Evaluation of the Accuracy and Use of X-Ray Markers in Digital Templating for Total Hip Arthroplasty
    Bayne, Christopher O.
    Krosin, Michael
    Barber, Thomas C.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (03) : 407 - 413
  • [42] Digital templating cementless short stem total hip arthroplasty: is there a difference in planning adherence between the direct anterior approach and minimally invasive anterolateral approach?
    Luger, Matthias
    Feldler, Sandra
    Schauer, Bernhard
    Hochgatterer, Rainer
    Gotterbarm, Tobias
    Klasan, Antonio
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (03) : 1619 - 1626
  • [43] Digital templating cementless short stem total hip arthroplasty: is there a difference in planning adherence between the direct anterior approach and minimally invasive anterolateral approach?
    Matthias Luger
    Sandra Feldler
    Bernhard Schauer
    Rainer Hochgatterer
    Tobias Gotterbarm
    Antonio Klasan
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 1619 - 1626
  • [44] Influence of calibration on digital templating of hip arthroplasty
    Christoph Kolja Boese
    Sebastian Wilhelm
    Stefan Haneder
    Philipp Lechler
    Peer Eysel
    Jan Bredow
    International Orthopaedics, 2019, 43 : 1799 - 1805
  • [45] Influence of calibration on digital templating of hip arthroplasty
    Boese, Christoph Kolja
    Wilhelm, Sebastian
    Haneder, Stefan
    Lechler, Philipp
    Eysel, Peer
    Bredow, Jan
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (08) : 1799 - 1805
  • [46] Preoperative digital templating of Birmingham hip resurfacing
    Konan, Sujith
    Rayan, Faizal
    Meermans, Geert
    Geurts, Jan
    Haddad, Fares S.
    HIP INTERNATIONAL, 2010, 20 (01) : 14 - 17
  • [47] Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty
    Riechelmann, Felix
    Lettner, H.
    Mayr, R.
    Tandogan, R.
    Dammerer, D.
    Liebensteiner, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (08) : 4705 - 4711
  • [48] Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty
    Felix Riechelmann
    H. Lettner
    R. Mayr
    R. Tandogan
    D. Dammerer
    M. Liebensteiner
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 4705 - 4711
  • [49] The Accuracy of Digital Templating for Primary Total Hip Arthroplasty: Is There a Difference Between Direct Anterior and Posterior Approaches?
    Shemesh, Shai S.
    Robinson, Jonathan
    Keswani, Aakash
    Bronson, Michael J.
    Moucha, Calin S.
    Chen, Darwin
    JOURNAL OF ARTHROPLASTY, 2017, 32 (06) : 1884 - 1889
  • [50] Accuracy of Digital Preoperative Templating in 100 Consecutive Uncemented Total Hip Arthroplasties A Single Surgeon Series
    Shaarani, Shahril R.
    McHugh, Gavin
    Collins, Denis A.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (02) : 331 - 337