The utility and precision of analogue and digital preoperative planning for total hip arthroplasty

被引:0
作者
Alejandro González Della Valle
Fernando Comba
Nicole Taveras
Eduardo A. Salvati
机构
[1] Weill Medical College of Cornell University,Hospital for Special Surgery
[2] Hospital Italiano de Buenos Aires,Institute of Orthopaedics “Carlos E. Ottolenghi”
来源
International Orthopaedics | 2008年 / 32卷
关键词
Stem Size; Digital Plan; Prosthetic Head; Digital Templating; Preoperative Templating;
D O I
暂无
中图分类号
学科分类号
摘要
We prospectively compared the utility and precision of preoperative templating performed in printed films (analogue) with that performed on digital radiographs (digital) in 69 patients undergoing primary total hip replacement. Five patients were excluded when misplacement of the marker resulted in a magnification error greater that 10%; in the remaining patients (64 hips), the cup size was within ± one size in 62 (97%) of the analogue and 52 (81%) of the digital (p = 0.01) plans. The stem size was within ± one size in 63 (98%) of the analogue and 60 (94%) of the digital (p = 0.39) plans. The distance from the proximal corner of the lesser trochanter to the center of the prosthetic head (LTCD) in the analogue differed by 5 mm or more from the digital plan in nine cases (14%). Analogue preoperative planning yielded more predictable results than digital planning, particularly in terms of acetabular component size and LTCD that dictates limb lengthening-shortening. The sources of error were not clearly explained by variations in magnification. Inconsistent positioning of the magnification marker may jeopardise the safe implementation of digital templating.
引用
收藏
页码:289 / 294
页数:5
相关论文
共 50 条
  • [21] Comparison of digital and plain radiography preoperative templating in total knee arthroplasty
    Lewis, J.
    Hossain, M.
    Mustafa, A.
    Sinha, A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2008, 18 (05) : 357 - 360
  • [22] Comparison of digital and plain radiography preoperative templating in total knee arthroplasty
    J. Lewis
    M. Hossain
    A. Mustafa
    A. Sinha
    European Journal of Orthopaedic Surgery & Traumatology, 2008, 18 : 357 - 360
  • [23] The accuracy of digital templating in cementless total hip arthroplasty in dysplastic hips
    Kristoffersson, Emelie
    Otten, Volker
    Crnalic, Sead
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [24] Digital templating in total hip arthroplasty in the NHS: 'computer says no...'
    Jeyaseelan, Luckshmana
    Ward, Jonathan
    Eleftheriou, Kyriacos
    Cobb, J.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2011, 21 (06) : 397 - 399
  • [25] Effect of Body Mass Index on Digital Templating for Total Hip Arthroplasty
    Sershon, Robert A.
    Diaz, Alejandro
    Bohl, Daniel D.
    Levine, Brett R.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (03) : 1024 - 1026
  • [26] The accuracy of digital templating in cementless total hip arthroplasty in dysplastic hips
    Emelie Kristoffersson
    Volker Otten
    Sead Crnalic
    BMC Musculoskeletal Disorders, 22
  • [27] Accuracy of a Simple Digital Templating in Primary Uncemented Total Hip Arthroplasty
    Hai-bo Si
    Yi Zeng
    Fei Cao
    Fu-xing Pei
    Bin Shen
    ChineseMedicalSciencesJournal, 2015, 30 (03) : 150 - 155
  • [28] Digital pre-operative templating is more accurate in total hip replacement compared to analogue templating
    M. Hossain
    J. Lewis
    A. Sinha
    European Journal of Orthopaedic Surgery & Traumatology, 2008, 18 : 577 - 580
  • [29] Digital templating in total hip arthroplasty using contralateral healthy hip results in decreased accuracy
    Shichman, Ittai
    Shaked, Or
    Morgan, Samuel
    Garceau, Simon
    Snir, Nimrod
    Warschawski, Yaniv
    ACTA ORTHOPAEDICA BELGICA, 2021, 87 (03): : 427 - 433
  • [30] Digital pre-operative templating is more accurate in total hip replacement compared to analogue templating
    Hossain, M.
    Lewis, J.
    Sinha, A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2008, 18 (08) : 577 - 580