The purpose of this study is to use high-resolution magnetic resonance (MR) imaging at 3 Tesla (3T) to quantify trabecular bone structure in vitro using femoral head specimens, and to correlate the calculated structure measures with those that were determined using microcomputed tomography (μCT), the standard of reference. Fifteen cylindrical cores were obtained from fresh femoral heads after total hip arthroplasty. MR images were obtained at 3T using a transmit–receive wrist coil. High-resolution coronal images were acquired using a modified three-dimensional (3D) fast-gradient echo sequence. From these data sets two-dimensional (2D) structural parameters analogous to bone histomorphometry were derived by using both mean intercept length (MIL) methods based on the plate model and the more recent model-assumption free 3D distance-transformation (DT) methods. The parameters measured by the 2D plate model-based MIL method and the DT method included apparent (App). BV/TV (bone volume/total volume), App. Tb.Th (trabecular thickness), App. Tb.Sp (trabecular separation), and App. Tb.N (trabecular number). Identical regions of interest were analyzed in the MR images and the μCT data sets, and similar structure measures were derived. The means and standard deviations of the parameters over all slices were calculated and MR-derived measures were correlated with those derived from the μCT data sets using linear regression analyses. Structure measures were overestimated with MRI, for example, the mean App. BV/TV was 0.45 for MRI and 0.20 for μCT, and the slope of the graph was 1.45. App. Tb.Th was overestimated by a factor of 1.9, whereas App. Tb.Sp was underestimated; Tb.N showed the smallest effect. Correlations between the individual parameters were excellent (App. BV/TV, r2= 0.82; App. Tb.Sp, r2 = 0.84; App. Tb.N, r2 = 0.81), except for App.Tb.Th (r2 = 0.67). The results of this study show that trabecular bone structure measures may be obtained using 3T MR imaging. These measures, although higher than the standard of reference, show a highly significant correlation with true structure measures obtained by μCT.
引用
收藏
页码:355 / 364
页数:9
相关论文
共 50 条
  • [1] Quantification of trabecular bone structure using magnetic resonance imaging at 3 Tesla-calibration studies using microcomputed tomography as a standard of reference
    Sell, CA
    Masi, JN
    Burghardt, A
    Newitt, D
    Link, TM
    Majumdar, S
    CALCIFIED TISSUE INTERNATIONAL, 2005, 76 (05) : 355 - 364
  • [2] Bone marrow quantification using 3.0 tesla magnetic resonance imaging
    Bernard, C. P.
    Liney, G. P.
    Manton, D. J.
    Turnbull, L. W.
    Langton, C. M.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2007, 22 (07) : 1140 - 1140
  • [3] Heterogeneity of trabecular bone structure in the calcaneus using magnetic resonance imaging
    Lin, JC
    Amling, M
    Newitt, DC
    Selby, K
    Srivastav, SK
    Delling, G
    Genant, HK
    Majumdar, S
    OSTEOPOROSIS INTERNATIONAL, 1998, 8 (01) : 16 - 24
  • [4] Heterogeneity of Trabecular Bone Structure in the Calcaneus Using Magnetic Resonance Imaging
    J.C. Lin
    M. Amling
    D.C. Newitt
    K. Selby
    S.K. Srivastav
    G. Delling
    H.K. Genant
    S. Majumdar
    Osteoporosis International, 1998, 8 : 16 - 24
  • [5] Quantification of trabecular structure in the distal femur using magnetic resonance phase imaging
    DeBisschop, E
    Luypaert, R
    Allein, S
    Osteaux, M
    MAGNETIC RESONANCE IMAGING, 1996, 14 (01) : 11 - 20
  • [6] EVALUATION OF TECHNICAL FACTORS AFFECTING THE QUANTIFICATION OF TRABECULAR BONE-STRUCTURE USING MAGNETIC-RESONANCE-IMAGING
    MAJUMDAR, S
    NEWITT, D
    JERGAS, M
    GIES, A
    CHIU, E
    OSMAN, D
    KELTNER, J
    KEYAK, J
    GENANT, H
    BONE, 1995, 17 (04) : 417 - 430
  • [7] Morphological characterization of trabecular bone structure using high resolution magnetic resonance imaging
    Nieto, L.
    Moratal, D.
    Marti-Bonmati, L.
    Albericha, A.
    Galant, J.
    RADIOLOGIA, 2008, 50 (05): : 401 - 408
  • [8] Reproducibility and accuracy in the morphometric and mechanical quantification of trabecular bone from 3 Tesla magnetic resonance images
    Alberich-Bayarri, A.
    Marti-Bonmati, L.
    Sanz-Requena, R.
    Sanchez-Gonzalez, J.
    Briz, V. Hervas
    Garcia-Marti, G.
    Perez, M. A.
    RADIOLOGIA, 2014, 56 (01): : 27 - 34
  • [9] DIAGNOSIS OF OSTEOARTHRITIS BY QUANTIFICATION OF TIBIA TRABECULAR BONE STRUCTURE FROM MAGNETIC RESONANCE IMAGING
    Marques, J.
    Dam, E.
    OSTEOARTHRITIS AND CARTILAGE, 2011, 19 : S75 - S76
  • [10] Assessment of trabecular bone structure comparing magnetic resonance imaging at 3 Tesla with high-resolution peripheral quantitative computed tomography ex vivo and in vivo
    Krug, R.
    Carballido-Gamio, J.
    Burghardt, A. J.
    Kazakia, G.
    Hyun, B. H.
    Jobke, B.
    Banerjee, S.
    Huber, M.
    Link, T. M.
    Majumdar, S.
    OSTEOPOROSIS INTERNATIONAL, 2008, 19 (05) : 653 - 661