Sparse-view image reconstruction in prospectively gated micro-CT for fast and low-dose imaging

被引:0
|
作者
Jonghwan Min
Gyuseong Cho
Seungryong Cho
Kyoungwoo Kim
机构
[1] Korea Advanced Institute of Science and Technology,Department of Nuclear and Quantum Engineering
[2] Nano Focus Ray (Co.,undefined
[3] Ltd.),undefined
来源
Journal of the Korean Physical Society | 2012年 / 60卷
关键词
Computed tomography; Animal imaging; Image reconstruction;
D O I
暂无
中图分类号
学科分类号
摘要
We conducted a feasibility study using a total-variation minimization algorithm for image reconstruction in prospectively gated micro computed tomography (micro-CT). The total-variation (TV) minimization algorithm exploits the sparseness of the image’s gradient magnitude and can successfully reconstruct CT images from undersampled data for which conventional analytic reconstruction algorithms fail. We implemented the algorithm and applied it to sparsely-sampled data for a mouse by using a prospectively gated micro-CT system. The images were successfully reconstructed, and an image similarity index was quantitatively calculated with respect to the reference images reconstructed from fully-sampled data. Compared to a conventional image reconstruction algorithm, the TV-minimization algorithm substantially reduced image inaccuracy related to the image artifacts.
引用
收藏
页码:1157 / 1160
页数:3
相关论文
共 50 条
  • [41] Low-dose CT reconstruction method based on prior information of normal-dose image
    Chen, Zixiang
    Zhang, Qiyang
    Zhou, Chao
    Zhang, Mengxi
    Yang, Yongfeng
    Liu, Xin
    Zheng, Hairong
    Liang, Dong
    Hu, Zhanli
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (06) : 1091 - 1111
  • [42] Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure
    Maier, Joscha
    Sawall, Stefan
    Kachelriess, Marc
    MEDICAL PHYSICS, 2014, 41 (05)
  • [43] Effects of sparse sampling schemes on image quality in low-dose CT
    Abbas, Sajid
    Lee, Taewon
    Shin, Sukyoung
    Lee, Rena
    Cho, Seungryong
    MEDICAL PHYSICS, 2013, 40 (11)
  • [44] Low-dose 4D cardiac imaging in small animals using dual source micro-CT
    Holbrook, M.
    Clark, D. P.
    Badea, C. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02)
  • [45] Accurate tissue characterization in low-dose CT imaging with pure iterative reconstruction
    Murphy, Kevin P.
    McLaughlin, Patrick D.
    Twomey, Maria
    Chan, Vincent E.
    Moloney, Fiachra
    Fung, Adrian J.
    Chan, Faimee E.
    Kao, Tafline
    O'Neill, Siobhan B.
    Watson, Benjamin
    O'Connor, Owen J.
    Maher, Michael M.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (02) : 190 - 196
  • [46] 3D Feature Constrained Reconstruction for Low-Dose CT Imaging
    Liu, Jin
    Hu, Yining
    Yang, Jian
    Chen, Yang
    Shu, Huazhong
    Luo, Limin
    Feng, Qianjing
    Gui, Zhiguo
    Coatrieux, Gouenou
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 2018, 28 (05) : 1232 - 1247
  • [47] Quantitative Comparison of Deep Learning-Based Image Reconstruction Methods for Low-Dose and Sparse-Angle CT Applications
    Leuschner, Johannes
    Schmidt, Maximilian
    Ganguly, Poulami Somanya
    Andriiashen, Vladyslav
    Coban, Sophia Bethany
    Denker, Alexander
    Bauer, Dominik
    Hadjifaradji, Amir
    Batenburg, Kees Joost
    Maass, Peter
    van Eijnatten, Maureen
    JOURNAL OF IMAGING, 2021, 7 (03)
  • [48] A Preliminary Investigation of Reduced-view Image Reconstruction from Low-dose Breast CT Data
    Bian, Junguo
    Han, Xiao
    Yang, Kai
    Sidky, Emil Y.
    Boone, John M.
    Pan, Xiaochuan
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [49] FAST FAN/PARALLEL BEAM CS-BASED LOW-DOSE CT RECONSTRUCTION
    Hashemi, SayedMasoud
    Beheshti, Soosan
    Gill, Patrick R.
    Paul, Narinder S.
    Cobbold, Richard S. C.
    2013 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2013, : 1099 - 1103
  • [50] An iterative reconstruction method for sparse-projection data for low-dose CT
    Huang, Ying
    Wan, Qian
    Chen, Zixiang
    Hu, Zhanli
    Cheng, Guanxun
    Qi, Yulong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (05) : 797 - 812