Energy-sensitive photon counting detector-based X-ray computed tomography

被引:74
|
作者
Taguchi K. [1 ]
机构
[1] Division of Medical Imaging Physics, The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 601 North Caroline Street, JHOC Room 4263, Baltimore, 21287, MD
关键词
Computed tomography; Photon counting; X-ray;
D O I
10.1007/s12194-017-0390-9
中图分类号
学科分类号
摘要
Energy-sensitive photon counting detectors (PCDs) have recently been developed for medical X-ray computed tomography (CT) imaging and a handful of prototype PCD-CT systems have been built and evaluated. PCDs detect X-rays by using mechanisms that are completely different from the current CT detectors (i.e., energy integrating detectors or EIDs); PCDs count photons and obtain the information of the object tissues (i.e., the effective atomic numbers and mass densities) to be imaged. Therefore, these PCDs have the potential not only for evolution—to improve the current CT images such as providing dose reduction—but also for a revolution—to enable novel applications with a new concept such as molecular CT imaging. The performance of PCDs, however, is not flawless, and thus, it requires integrated efforts to develop PCD-CT for clinical use. In this article, we review the current status and the prediction for the future of PCDs, PCD-CT systems, and potential clinical applications. © 2017, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:8 / 22
页数:14
相关论文
共 50 条
  • [31] Indirect photon-counting x-ray imaging using CMOS Photon Detector (CPD)
    Nishihara, Toshiyuki
    Baba, Hiroyasu
    Matsumura, Masao
    Kumagai, Oichi
    Izawa, Takashi
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [32] Characteristic evaluation of a novel CdTe photon counting detector for X-ray imaging
    Hyo-Min Cho
    Hee-Joung Kim
    Hyun-Ju Ryu
    Yu-Na Choi
    Journal of the Korean Physical Society, 2013, 63 : 120 - 127
  • [33] Quantitative material decomposition using spectral computed tomography with an energy-resolved photon-counting detector
    Lee, Seungwan
    Choi, Yu-Na
    Kim, Hee-Joung
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18): : 5457 - 5482
  • [34] Photon counting x-ray detectors as scatter probes
    Lahoud, Elias
    Zaffrani, Yael
    Yagil, Yoad
    MEDICAL PHYSICS, 2024, 51 (01) : 93 - 102
  • [35] Performance Evaluation of a Modular Detector Unit for X-Ray Computed Tomography
    Guo, Zhe
    Tang, Zhiwei
    Wang, Xinzeng
    Deng, Mingliang
    Hu, Guangshu
    Zhang, Hui
    SENSORS, 2013, 13 (04): : 5167 - 5180
  • [36] Research of Photon Counting Dual-energy X-ray Absorptiometry Based on SiPM
    Wu, Zhongyi
    Du, Qiang
    Mo, Jingqing
    Tsui, Benjamin M. W.
    Sun, Mingshan
    Xi, Daoming
    Yuan, Gang
    Zheng, Jian
    Yang, Xiaodong
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [37] Photon-counting x-ray detectors for CT
    Danielsson, Mats
    Persson, Mats
    Sjolin, Martin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03):
  • [38] Enabling Photon Counting Clinical X-ray CT
    Taguchi, Katsuyuki
    Srivastava, Somesh
    Kudo, Hiroyuki
    Barber, William C.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3581 - +
  • [39] Filter-based energy-resolved X-ray computed tomography with a clinical imager
    Tsai, Tien-Hsiu
    Hamaguchi, Takumi
    Iramina, Hiraku
    Nakamura, Mitsuhiro
    Kanno, Ikuo
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2019, 56 (02) : 210 - 220
  • [40] Photon counting multienergy x-ray imaging: Effect of the characteristic x rays on detector performance
    Shikhaliev, Polad M.
    Fritz, Shannon G.
    Chapman, John W.
    MEDICAL PHYSICS, 2009, 36 (11) : 5107 - 5119