共 46 条
Overshoot phenomenon of oxygen uptake during recovery from maximal exercise in patients with previous myocardial infarction
被引:0
作者:
Osamu Nagayama
Akira Koike
Takeya Suzuki
Masayo Hoshimoto-Iwamoto
Hitoshi Sawada
Tadanori Aizawa
机构:
[1] The Cardiovascular Institute,Department of Cardiovascular Medicine
[2] Toho University Omori Medical Center,School of Health and Sports Science
[3] Juntendo University,undefined
来源:
The Journal of Physiological Sciences
|
2010年
/
60卷
关键词:
Exercise recovery;
Exercise testing;
Oxygen uptake;
Previous myocardial infarction;
D O I:
暂无
中图分类号:
学科分类号:
摘要:
The overshoot in oxygen uptake (\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \dot{\rm{V}} $$\end{document}O2 overshoot) during recovery from maximal exercise is thought to reflect an overshoot in cardiac output. We investigated whether this phenomenon is related to cardiopulmonary function during exercise in cardiac patients. A total of 201 consecutive patients with previous myocardial infarction underwent cardiopulmonary exercise testing (CPX). An apparent \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \dot{\rm{V}} $$\end{document}O2 overshoot during the recovery from CPX (6.5 ± 8.1% increase relative to the peak \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \dot{\rm{V}} $$\end{document}O2) was observed in ten patients. A comparison of patients with the \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \dot{\rm{V}} $$\end{document}O2 overshoot to those without the \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \dot{\rm{V}} $$\end{document}O2 overshoot revealed that the former had a significantly lower left ventricular ejection fraction (40.1 ± 19.1 vs. 55. 2 ± 14.9%, respectively, p = 0.002) and larger left ventricular diastolic and systolic dimensions. Patients with the \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \dot{\rm{V}} $$\end{document}O2 overshoot also had a significantly lower peak \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \dot{\rm{V}} $$\end{document}O2 (13.1 ± 6.1 vs. 18.1 ± 4.5 ml/min/kg, p < 0.001), lower Δ\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \dot{\rm{V}} $$\end{document}O2/ΔWR (work rate) (6.6 ± 3.8 vs. 9.5 ± 1.7 mL/min/W, p < 0.0001), and a higher \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \dot{\rm{V}} $$\end{document}E (minute ventilation)/\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \dot{\rm{V}} $$\end{document}CO2 (carbon dioxide output) slope (45.0 ± 18.6 vs. 32.6 ± 6.6, p < 0.0001) than those without the overshoot. A \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \dot{\rm{V}} $$\end{document}O2 overshoot during recovery from maximal exercise was found in 5% of patients with previous myocardial infarction. This condition, which suggests a transient mismatch between cardiac contractility and afterload reduction, was found to be related to impaired cardiopulmonary function during exercise.
引用
收藏
页码:137 / 142
页数:5
相关论文