Finite Element Analysis of the Current-Density and Electric Field Generated by Metal Microelectrodes

被引:0
作者
Cameron C. McIntyre
Warren M. Grill
机构
[1] Case Western Reserve University,Department of Biomedical Engineering
来源
Annals of Biomedical Engineering | 2001年 / 29卷
关键词
Electrode; Electrical stimulation; Neural stimulation; Tissue damage; Electric fields; Bioelectricity;
D O I
暂无
中图分类号
学科分类号
摘要
Electrical stimulation via implanted microelectrodes permits excitation of small, highly localized populations of neurons, and allows access to features of neuronal organization that are not accessible with larger electrodes implanted on the surface of the brain or spinal cord. As a result there are a wide range of potential applications for the use of microelectrodes in neural engineering. However, little is known about the current-density and electric field generated by microelectrodes. The objectives of this project were to answer three fundamental questions regarding electrical stimulation with metal microelectrodes using geometrically and electrically accurate finite elements models. First, what is the spatial distribution of the current density over the surface of the electrode? Second, how do alterations in the electrode geometry effect neural excitation? Third, under what conditions can an electrode of finite size be modeled as a point source? Analysis of the models showed that the current density was concentrated at the tip of the microelectrode and at the electrode–insulation interface. Changing the surface area of the electrode, radius of curvature of the electrode tip, or applying a resistive coating to the electrode surface altered the current-density distribution on the surface of the electrode. Changes in the electrode geometry had little effect on neural excitation patterns, and modeling the electric field generated by sharply tipped microelectrodes using a theoretical point source was valid for distances >∼ 50μm from the electrode tip. The results of this study suggest that a nearly uniform current-density distribution along the surface of the electrode can be achieved using a relatively large surface area electrode μ00--1000μm2), with a relatively blunt tip (3–6 μm radius of curvature), in combination with∼mμ∼ 1μm) moderately resistive ∼( ∼ 50Ωm). © 2001 Biomedical Engineering Society.
引用
收藏
页码:227 / 235
页数:8
相关论文
共 113 条
[1]  
Bagshaw E. V.(1976)Measurement of current spread from microelectrodes when stimulating within the nervous system Exp. Brain Res. 25 391-400
[2]  
Evans M. H.(1999)Tapping into spinal circuits to restore motor function Brain Res. Rev. 30 27-51
[3]  
Barbeau H.(1977)Electrical stimulation with Pt electrodes I: a method for determination of “real” electrode areas IEEE Trans. Biomed. Eng. 24 436-439
[4]  
McCrea D. A.(1977)Electrical stimulation with Pt electrodes II: estimation of maximum surface redox (theoretical non gassing) limits IEEE Trans. Biomed. Eng. 24 440-443
[5]  
Donovan M. J. O.(1977)Electrical stimulation with Pt electrodes: trace analysis for dissolved platinum and other dissolved electrochemical products Brain Behav. Evol. 14 10-22
[6]  
Rossingol S.(1995)Micturition control by microstimulation of the sacral spinal cord of the cat: acute studies IEEE Trans. Rehab. Eng. 3 206-214
[7]  
Grill W. M.(1983)Two methods for homogenous field defibrillation and stimulation Med. Biol. Eng. Comput. 21 518-520
[8]  
Lemay M. A.(1994)Electrical properties of implant encapsulation tissue Ann. Biomed. Eng. 22 23-33
[9]  
Brummer S. B.(1999)Bladder and urethral pressure evoked by microstimulation of the sacral spinal cord in cats Brain Res. 836 19-30
[10]  
Turner M. J.(2000)Reduction in excitability of the auditory nerve following electrical stimulation at high stimulus rates: V. effects of electrode surface area Hear. Res. 146 57-71