In-Plane Shear-Wall Configuration Effects on the Seismic Performance of Symmetrical Multistory Reinforced-Concrete Buildings

被引:0
作者
Sayed Mahmoud
机构
[1] Imam Abdulrahman Bin Faisal University,Department of Civil and Construction Engineering, College of Engineering
来源
International Journal of Civil Engineering | 2021年 / 19卷
关键词
RC buildings; Shear walls; Configuration; Location; Seismic response;
D O I
暂无
中图分类号
学科分类号
摘要
Shear walls, which are vertical elements with significantly high stiffness values, are becoming more and more popular and are widely used as primary lateral-load-resisting systems for reinforced-concrete (RC) buildings of various heights to ensure satisfactory performance. This study is thus devoted to assessing the performance of RC buildings with shear walls of different locations and configurations under the effect of seven different earthquake motions representing near‐source records. The buildings were designed to fit regions of medium seismicity following the ASCE 7–10 design requirements. Finite-element models were developed with shear walls, distributed over either the outer panel, the intermediate panel, or the center of the building. The seismic assessment of the developed building models was performed using dynamic nonlinear time–history analysis employing the selected full set of records. The results from the analysis clarified that the configuration and location of shear walls tend to significantly affect the induced story seismic responses. More specifically, building models with central core system, Configuration 7, provide the highest seismic responses among all other building models with about 50% which may lead to cost-effective earthquake-resistant design. From base shear design point of view, the use of shear walls distributed as parallel pairs along either the peripheral or the intermediate panel, Configurations 3 and 6, are the advantageous where they substantially reduce base shear by at least 33.20% among all other configurations.
引用
收藏
页码:1195 / 1208
页数:13
相关论文
共 39 条
  • [1] Brencich A(2012)Failure case studies in structural engineering courses and professional practice Arab J Sci Eng 37 2113-2126
  • [2] Gnecco M(2013)Assessment of shear wall quantity in seismic-resistant design of reinforced concrete buildings Arab J Sci Eng 38 2639-2648
  • [3] Tuken A(1992)Ductility and detailing requirements of bearing wall buildings J Struct Eng 118 1625-1644
  • [4] Siddiqui NA(1994)Anew methodology for seismic design of reinforced concrete shear walls J Struct Eng 120 863-884
  • [5] Wallace JW(2013)Effect of shear wall area to floor area ratio on the seismic behavior of reinforced concrete buildings J Struct Eng ASCE 139 1928-1937
  • [6] Moehle JP(2020)Effect of ductile shear wall ratio and cross-section configuration on seismic behavior of reinforced concrete masonry shear wall buildings J Struct Eng 146 04020020-14
  • [7] Wallace JW(2020)Effect of stiffness on the seismic performance of code-conforming reinforced concrete shear wall buildings Eng Struct 219 1-584
  • [8] Burak B(2017)Seismic performance of high-rise RC shear wall buildings subjected to ground motions with various frequency contents Civil Eng J 3 568-234
  • [9] Comlekoglu HG(2016)Seismic assessment of slender high-rise buildings with different shear walls configurations Adv Comput Des 1 221-162
  • [10] Aly N(2017)Optimum positioning of shear walls for minimizing the effects of lateral forces in multistory-buildings Arch Civ Eng LXIII 1 151-440