Normal values and standardization of parameters in nuclear cardiology: Japanese Society of Nuclear Medicine working group database

被引:0
作者
Kenichi Nakajima
Naoya Matsumoto
Tokuo Kasai
Shinro Matsuo
Keisuke Kiso
Koichi Okuda
机构
[1] Kanazawa University Hospital,Department of Nuclear Medicine
[2] Nihon University Hospital,Department of Cardiology
[3] Tokyo Medical University Hachioji Medical Center,Department of Cardiology
[4] National Cerebral and Cardiovascular Center,Department of Radiology
[5] Kanazawa Medical University,Department of Physics
来源
Annals of Nuclear Medicine | 2016年 / 30卷
关键词
Japanese Society of Nuclear Medicine (JSNM) working group; Normal database; Myocardial perfusion imaging; I-Metaiodobenzylguanidine (MIBG) quantification;
D O I
暂无
中图分类号
学科分类号
摘要
As a 2-year project of the Japanese Society of Nuclear Medicine working group activity, normal myocardial imaging databases were accumulated and summarized. Stress-rest with gated and non-gated image sets were accumulated for myocardial perfusion imaging and could be used for perfusion defect scoring and normal left ventricular (LV) function analysis. For single-photon emission computed tomography (SPECT) with multi-focal collimator design, databases of supine and prone positions and computed tomography (CT)-based attenuation correction were created. The CT-based correction provided similar perfusion patterns between genders. In phase analysis of gated myocardial perfusion SPECT, a new approach for analyzing dyssynchrony, normal ranges of parameters for phase bandwidth, standard deviation and entropy were determined in four software programs. Although the results were not interchangeable, dependency on gender, ejection fraction and volumes were common characteristics of these parameters. Standardization of 123I-MIBG sympathetic imaging was performed regarding heart-to-mediastinum ratio (HMR) using a calibration phantom method. The HMRs from any collimator types could be converted to the value with medium-energy comparable collimators. Appropriate quantification based on common normal databases and standard technology could play a pivotal role for clinical practice and researches.
引用
收藏
页码:188 / 199
页数:11
相关论文
共 351 条
  • [1] Nakajima K(2010)Normal values for nuclear cardiology: Japanese databases for myocardial perfusion, fatty acid and sympathetic imaging and left ventricular function Ann Nucl Med 24 125-135
  • [2] Go V(2004)The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging J Nucl Med 45 912-921
  • [3] Bhatt MR(1993)Left ventricular ejection fraction assessed from gated technetium-99 m-sestamibi SPECT J Nucl Med 34 1871-1876
  • [4] Hendel RC(1995)Automatic quantification of ejection fraction from gated myocardial perfusion SPECT J Nucl Med 36 2138-2147
  • [5] DePuey EG(2007)The increasing role of quantification in clinical nuclear cardiology: the Emory approach J Nucl Cardiol 14 420-432
  • [6] Nichols K(2007)Quantitation in gated perfusion SPECT imaging: the Cedars-Sinai approach J Nucl Cardiol 14 433-454
  • [7] Dobrinsky C(2007)Corridor4DM: the Michigan method for quantitative nuclear cardiology J Nucl Cardiol 14 455-465
  • [8] Germano G(2014)Myocardial image analysis software Heart Risk View, Heart Score View and Heart Function View (In Japanese) Kakuigaku Gijutsu (Nucl Med Techonology) 34 136-144
  • [9] Kiat H(2014)Clinical usefulness of a novel program “Heart Function View” for evaluating cardiac function from gated myocardial perfusion SPECT Ann Nucl Med 28 812-823
  • [10] Kavanagh PB(2013)Improved quantification of small hearts for gated myocardial perfusion imaging Eur J Nucl Med Mol Imaging 40 1163-1170