Comparison between central corneal thickness measurements by oculus pentacam and ultrasonic pachymetry

被引:67
作者
Al-Mezaine H.S. [1 ]
Al-Amro S.A. [1 ]
Kangave D. [2 ]
Sadaawy A. [3 ]
Wehaib T.A. [3 ]
Al-Obeidan S. [1 ]
机构
[1] Department of Ophthalmology, College of Medicine, King Saud University, Riyadh 11321
[2] Diabetes Research Center, College of Medicine, King Saud University, Riyadh 11321
[3] The Eye Consultants Center, Riyadh
关键词
Agreement; Corneal thickness; Pachymetry; Pentacam; Ultrasound;
D O I
10.1007/s10792-007-9143-9
中图分类号
学科分类号
摘要
Purpose: To compare the accuracy of central corneal thickness (CCT) measurements by the oculus pentacam scheimpflug system, with those obtained with the DGH ultrasound pachymeter (UP) and to assess the agreement between the two devices. Methods: In a prospective study, measurement agreement was assessed in 984 eyes of 492 healthy subjects using both oculus pentacam and ultrasonic pachymetry at the Eye Consultants Center, Riyadh, Saudi Arabia. Result: In the measurement agreement experiment, the mean CCT was 552.4 ± 37.0 μm with oculus pentacam and 544.1 ± 35.4 μm with ultrasonic pachymetry. Regression analysis showed a high correlation between the values obtained with both devices (r = 0.912, P < 0.001). Compared with UP, pentacam overestimated the CCT by a mean of 8.2 μm as demonstrated in a Bland-Altman plot. Conclusion: the CCT measurements by the pentacam and UP are highly correlated. The pentacam agrees well with UP and is a reliable alternative to UP in CCT measurements. © Springer Science+Business Media B.V. 2007.
引用
收藏
页码:333 / 338
页数:5
相关论文
共 31 条
[1]  
Marsich M.M., Bullimore M.A., The repeatability of corneal thickness measures, Cornea, 19, pp. 792-795, (2000)
[2]  
Bovelle R., Kaufman S.C., Thompson H.W., Hamano H., Corneal thickness measurements with the Topcon SP-2000P specular microscope and an ultrasound pachymeter, Arch Ophthalmol, 117, pp. 868-870, (1999)
[3]  
Modis Jr. L., Langenbucher A., Seitz B., Corneal thickness measurements with contact, non contact specular microscopic and ultrasonic pachymetry, Am J Ophthalmol, 132, pp. 517-521, (2001)
[4]  
Bechmann M., Thiel M.J., Neubauer A.S., Et al., Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry, Cornea, 20, pp. 50-54, (2001)
[5]  
Avitabile T., Marano F., Uva M.G., Reibaldi A., Evaluation of central and peripheral corneal thickness with ultrasound biomicroscopy in normal and keratoconic eyes, Cornea, 16, pp. 639-644, (1997)
[6]  
Tam E.S., Rootman D.S., Comparison of central corneal thickness measurements by specular microscopy, ultrasound pachymetry, and ultrasound biomicroscopy, J Cataract Refract Surg, 29, pp. 1179-1184, (2003)
[7]  
Yaylali V., Kaufman S.C., Thompson H.W., Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry, J Cataract Refract Surg, 23, pp. 1345-1350, (1997)
[8]  
Fakhry M.A., Artola A., Beida J.I., Et al., Comparison of corneal pachymetry using ultrasound and Orbscan II, J Cataract Refract Surg, 28, pp. 248-252, (2002)
[9]  
Boscia F., La Tegola M.G., Alessio G., Sborgia C., Accuracy of Orbscan optical pachymetry in corneas with haze, J Cataract Refract Surg, 28, pp. 253-258, (2002)
[10]  
Gonzalez-Meijome J.M., Cervh