Terahertz Detection Based on Spectral-Domain Interferometry Using Mach-Zehnder Interferometer

被引:0
|
作者
Akram Ibrahim
Gargi Sharma
Kanwarpal Singh
Tsuneyuki Ozaki
机构
[1] Université du Québec,INRS
[2] University of Massachusetts Lowell,EMT, Advanced Laser Light Source
[3] Harvard Medical School,Massachusetts General Hospital
来源
Journal of Infrared, Millimeter, and Terahertz Waves | 2016年 / 37卷
关键词
Spectral-domain interferometry; Mach-Zehnder interferometer; Intense terahertz electric field; Over-rotation;
D O I
暂无
中图分类号
学科分类号
摘要
We demonstrate the use of a Mach-Zehnder interferometer (MZI) to improve the performance of terahertz electric field measurements based on spectral-domain interferometry. The interferometer is introduced into the probe beam line to improve the temporal overlap between the two probe pulses. The probe pulse in the sample arm of the interferometer passes through the detection crystal and overlaps with the terahertz pulse, while the probe pulse in the reference arm does not. We measure the phase change between spectral components of these two pulses using spectral-domain interferometry. Using this new technique, we enable an unlimited temporal scanning window without the loss in the signal-to-noise ratio, thus overcoming the major limitation of conventional spectral-domain interferometry techniques for terahertz electric field detection.
引用
收藏
页码:837 / 845
页数:8
相关论文
共 50 条
  • [21] All-optical XOR using Mach-Zehnder interferometer
    Dutta, NK
    Wang, Q
    Zhu, G
    Chen, H
    Jaques, J
    Leuthold, J
    ACTIVE AND PASSIVE OPTICAL COMPONENTS FOR WDM COMMUNICATIONS IV, 2004, 5595 : 269 - 276
  • [22] Using a Mach-Zehnder interferometer to deduce nitrogen density mapping
    Boudaoud, F.
    Lemerini, M.
    CHINESE PHYSICS B, 2015, 24 (07)
  • [23] Absolute angular displacement determination using a Mach-Zehnder interferometer
    Lin, S. T.
    Yeh, S. L.
    Chang, C. W.
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2008, 10 (09):
  • [24] Optical fiber Mach-Zehnder interferometer based on a pair of microholes
    Wang, Jianguo
    Wang, D. N.
    Ge, Yunpeng
    Xu, Ben
    Guo, Xiaodong
    OPTICAL FIBER TECHNOLOGY, 2022, 73
  • [25] Signal amplification based on the local nonlinear Mach-Zehnder interferometer
    Srivastava, Arpita
    Gupta, Man Mohan
    Medhekar, S.
    OPTICS AND LASER TECHNOLOGY, 2012, 44 (02) : 492 - 496
  • [26] A novel method to monitor OSNR using a Mach-Zehnder interferometer
    Tao, ZN
    Chen, ZY
    Fu, LB
    Wu, DM
    Xu, AS
    CLEO(R)/PACIFIC RIM 2001, VOL II, TECHNICAL DIGEST, 2001, : 564 - 565
  • [27] Asymmetric Mach-Zehnder Interferometer Based Biosensors for Aflatoxin M1 Detection
    Chalyan, Tatevik
    Guider, Romain
    Pasquardini, Laura
    Zanetti, Manuela
    Falke, Floris
    Schreuder, Erik
    Heideman, Rene G.
    Pederzolli, Cecilia
    Pavesi, Lorenzo
    BIOSENSORS-BASEL, 2016, 6 (01):
  • [28] A Mach-Zehnder interferometer based on silicon oxides for biosensor applications
    Hong, Jongin
    Choi, Jung Sung
    Han, Gayoung
    Kang, Jae Kwang
    Kim, Chang-Min
    Kim, Tae Song
    Yoon, Dae Sung
    ANALYTICA CHIMICA ACTA, 2006, 573 : 97 - 103
  • [29] Research on the weak signal detection technique based on optical fiber Mach-Zehnder interferometer
    Tao, Peilin
    Yan, Fengping
    Tan, Zhongwei
    Liu, Yan
    Yin, Guolu
    Jian, Shuisheng
    2010 INTERNATIONAL CONFERENCE ON DISPLAY AND PHOTONICS, 2010, 7749
  • [30] Plasmonic Mach-Zehnder interferometer based on graphene sheets and resonators
    Wang, Jicheng
    Liang, Xiuye
    Xia, Xiushan
    Tang, Baojie
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2017, 11 (1-2): : 17 - 22