Effect of noise correlation in channels of a digital x-ray detector-converter on evaluation of detection quantum efficiency

被引:0
|
作者
Porosev V.V. [1 ]
Shekhtman L.I. [1 ]
Zelikman M.I. [2 ]
Blinov Jr. N.N. [3 ]
机构
[1] Budker Institute of Nuclear Physics, Siberian Division, Russian Academy of Sciences, Novosibirsk
[2] Sci.-Pract. Ctr. for Med. Radiology, Moscow Committee for Health, Moscow
[3] Amico, Ltd., Moscow
关键词
Quantum Efficiency; Noise Correlation; Detection Quantum; Detection Quantum Efficiency;
D O I
10.1007/s10527-005-0005-3
中图分类号
学科分类号
摘要
[No abstract available]
引用
收藏
页码:233 / 236
页数:3
相关论文
共 50 条
  • [31] Development of a built-in Analog-to-Digital Converter for a X-ray Astronomy Detector with the SOI CMOS Technology
    Nakashima, Shinya
    Ryu, Syukyo G.
    Tsuru, Takeshi G.
    Arai, Yasuo
    Takeda, Ayaki
    Nakajima, Hiroshi
    Tsunemi, Hiroshi
    Doty, John P.
    Imamura, Toshifumi
    Ohmoto, Takafumi
    Maeda, Tomoaki
    Iwata, Atsushi
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1201 - 1203
  • [32] Dose efficiency and low-contrast detectability of an amorphous silicon x-ray detector for digital radiography
    Aufrichtig, R
    Xue, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : 2653 - 2669
  • [33] Experimental evaluation of a-Se flat-panel X-ray detector for digital radiography
    Choi, JY
    Park, JK
    Lee, DG
    Kang, SS
    Nam, SH
    NEW APPLICATIONS FOR WIDE-BANDGAP SEMICONDUCTORS, 2003, 764 : 265 - 270
  • [34] USE OF EGS4 FOR THE EVALUATION OF THE PERFORMANCE OF A SILICON DETECTOR FOR X-RAY DIGITAL RADIOGRAPHY
    BENCIVELLI, W
    BERTOLUCCI, E
    BOTTIGLI, U
    DELGUERRA, A
    MAZZEI, D
    MESSINEO, A
    NELSON, WR
    RANDACCIO, P
    ROSSO, V
    RUSSO, P
    STEFANINI, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 305 (03): : 574 - 580
  • [35] Experimental evaluation of a-Se flat-panel X-ray detector for digital radiography
    Kim, JY
    Park, JK
    Choi, JY
    Cha, BY
    Kang, SS
    An, SH
    Nam, SH
    Choi, HK
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4048 - 4052
  • [36] Effects of characteristic x rays on the noise power spectra and detective quantum efficiency of photoconductive x-ray detectors
    Zhao, W
    Ji, WG
    Rowlands, JA
    MEDICAL PHYSICS, 2001, 28 (10) : 2039 - 2049
  • [37] Detection Quantum Efficiency (DQE) of X-Ray Film - Amplifying Screen System.
    Hoeschen, Dietmar
    Stargardt, Achim
    Mirande, Werner
    PTB - Mitteilungen Forschen und Prufen, 1988, 98 (02): : 128 - 138
  • [38] Quantum Efficiency Measurement and Modeling of Silicon Sensors Optimized for Soft X-ray Detection
    Carulla, Maria
    Barten, Rebecca
    Baruffaldi, Filippo
    Bergamaschi, Anna
    Borghi, Giacomo
    Boscardin, Maurizio
    Brueckner, Martin
    Butcher, Tim A.
    Vignali, Matteo Centis
    Dinapoli, Roberto
    Ebner, Simon
    Ficorella, Francesco
    Froejdh, Erik
    Greiffenberg, Dominic
    Ali, Omar Hammad
    Hasanaj, Shqipe
    Heymes, Julian
    Hinger, Viktoria
    King, Thomas
    Kozlowski, Pawel
    Lopez Cuenca, Carlos
    Mezza, Davide
    Moustakas, Konstantinos
    Mozzanica, Aldo
    Paternoster, Giovanni
    Paton, Kirsty A.
    Ronchin, Sabina
    Ruder, Christian
    Schmitt, Bernd
    Sieberer, Patrick
    Thattil, Dhanya
    Vogelsang, Konrad
    Xie, Xiangyu
    Zhang, Jiaguo
    SENSORS, 2024, 24 (03)
  • [39] Quantum efficiency calibration for low energy detector onboard hard X-ray modulation telescope satellite
    Zhu-Yue
    Zhang Zi-Liang
    Yang Yan-Ji
    Xue Rong-Feng
    Cui Wei-Wei
    Lu Bo
    Wang Juan
    Chen Tian-Xiang
    Wang Yu-Sa
    Li Wei
    Han Da-Wei
    Huo Jia
    Hu Wei
    Li Mao-Shun
    Zhang Yi
    Zhu Yu-Xuan
    Liu Miao
    Zhao Xiao-Fan
    Chen Yong
    ACTA PHYSICA SINICA, 2017, 66 (11)
  • [40] LENS COUPLED SCINTILLATING SCREEN CCD X-RAY AREA DETECTOR WITH A HIGH DETECTIVE QUANTUM EFFICIENCY
    KOCH, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 654 - 658